If a fire breaks out, evacuate the machine in the following
way:
NOTE: Beside emergency engine stop switch (6)
provided in the cab, two switches are located in
engine compartment and one in pump
compartment.
1. Stop the engines by turning emergency engine stop
switch (6) to the EMERG STOP position if there is
time.
2. Pull the pilot control shut-off lever to the LOCK posi-
tion.
3. Use a fire extinguisher if there is time.
4. Exit the machine in the following manner, depending
on the location of the fire.
If engine compartment sidewalk (7) is not on fire,
evacuate from the machine to the ground through cab
door (12), step (9), sidewalk (7) and lower stairway
(8).
If the engine compartment sidewalk (7) is on fire, first
evacuate from cab (11) through cab door (12) to cab
side platform (10). Then, get off the machine using
emergency device (5).
Emergency device (5) is provided in the case located
on the left outside wall of the cab. (See the "EMER-
GENCY ESCAPE" section.)
If the fire is around cab door (12), evacuate the cab by
opening left window, and stepping to platform (10).
Then, get off the machine using the emergency rope.
If left window cannot be opened, break the window-
pane using emergency evacuation tool (2) to gain ac-
cess to platform (10).
WARNING: Avoid possible injury to your eyes.
Wear a pair of safety glasses or goggles when
breaking windowpane with emergency evacua-
tion tool (2).
HANDLING STAIRWAY/EMERGENCY ROPE
12
11
10
1-7
5
9
M118-07-109
6
M18M-01-004
7
8
M18M-01-005
2
M18G-01-010