OPERATION

STARTING THE GENERATOR SET
NOTICE
A hot engine will not start if there is too much gasoline in the
cylinder. If this happens, wait for 5 to 10 minutes for the engine
to cool down before starting.
The engine will stop automatically when it is out of gasoline.
When the output indicator light (green) does not light and the
overload indicator light (red) lights instead, set the engine switch
to STOP, stop the engine at once and then start the engine again.
RECOIL START
1.
Rotate the fuel switch to the ON position according to the arrow
direction.
2.
Flip the engine switch to the ON position.
3.
Pull the starting grip lightly until resistance is felt, then pull briskly to
start the engine. (Refer to Fig.)
WARNING
Do not allow the starter grip to snap back. Return it slowly by
hand
Grasp the carrying handle firmly to prevent the generator from
falling over when pulling the starting grip