Hyundai HY300SEI User Manual page 24

Portable inverter
Table of Contents

Advertisement

Overload
indicator
light keeps
flashing
No DC
output
Generator
Connected
outputs
device does
unstable
not operate
power
consistently
Device will
not start up
Engine idle
unusually
high or low
Generator
Operation is
overheats
normal when
generator is
cool, over-
heating oc-
curs within
moments of
start up.
24
1.
Adjust choke lever according to instruc-
tions on page 12
*When a connected device draws high startup
power the overload and output indicator light may
briefly illuminate, but this is to be expected. Once
the device starts up the overload indicator light
will shut off and the output light will remain green.
2.
Ensure device wattage consumption does
not exceed the generator's maximum peak
output.
1.
Disconnect battery, reset breaker and test
the battery for shorts.
2.
Clean battery connector nodes.
Verify device start up requirements (Wattage
consumption). Do not exceed the generators
maximum peak output.
1.
Remove all loads, reset breaker, and check
device for defects. Do not exceed genera-
tor rating.
2.
Ensure device's wattage consumption
does not exceed the generator's maximum
peak output.
Carburetor in need of tuning. For details on how
to adjust correctly please contact your local
service centre, or contact Midland Intl Inc. at
1-877-528-3772.
1.
Atmospheric temperature high (excess
of 35°C).
2.
Insufficient air circulation in vicinity of
generator.
3.
Low oil viscosity, use 10W40 when
temperatures exceed 30°C, 10W30 for
temperatures between 0° ~ 30°C, and
5W40 for temperatures below 0°C.
4.
Fouled spark plug, replace with equal or
greater quality plug.
HY3000sei User Manual