BUZZER OPERATE
YES – ENIGMA II buzzer is on, yo can hear buzzer sound if there is new event until
manual acknowledge (pushing ENTER button) / monitoring software acknowledge.
NO – ENIGMA II buzzer is off, there is no buzzer signal in case of unacknowledged
event.
F2 (PORTS) / F1 (COM A) or F2 (COM B)
CONSOLE
OPERATION MODE
RECEIVER ID
PORT SETTING
+
F1
It is recommended to modify the following settings only:
OPERATION MODE
NORMAL – ENIGMA II forwards data on the given port towards monitoring software
(default port for PC connection).
RECEIVE – ENIGMA II can only receive data on the given port (this port is to connect
another receiver to ENIGMA II, or for reserve port).
Note: COM A and USB A ports are equivalent, as the COM B and USB B ports. Do not
connect devices at the same time to COM A and USB A ports. If it is possible, always
recommended to use COM A as against USB A.
Note: If the A serial port of the receiver has any trouble, B port can work as a
replacement. For this switch on OPERATION MODE to RECEIVE on port A, and to
NORMAL on port B. Please connect PC connector from port A to port B.
SERIAL PORT A
NORMAL
01
9600, 8, NONE
F2
9
VER: CPM2.60.BC06
PAGE
CANCEL
F3
F4