ENIGMA II DR-81000 User Manual

ENIGMA II DR-81000 User Manual

V2.00 digital receiver
Hide thumbs Also See for DR-81000:
Table of Contents

Advertisement

ENIGMA II
DR-81000 V2.00
Digital Receiver
User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DR-81000 and is the answer not in the manual?

Questions and answers

Summary of Contents for ENIGMA II DR-81000

  • Page 1 ENIGMA II DR-81000 V2.00 Digital Receiver User Manual...
  • Page 2: Table Of Contents

    Install Additional Line Cards......10 TCP/IP Options ..........22 ENIGMA II Backplane View .......10 6. LC2 Line Card ........23 4. The ENIGMA II Controls ..... 11 General Information ........23 The LCD Display ..........11 Installation ..........23 Power LED ............11 Bat LED ............
  • Page 3 ENIGMA II DR-81000 Digital Receiver Version 2.00 Stand-by Mode........... 24 7. Power Card ..........30 CPM2 Monitoring ..........24 Inputs and Outputs........... 30 Call Reception..........25 Power Status Display........30 2-way Audio Mode ........... 25 Battery Testing ..........30 Call Termination..........25 Appendices..........31...
  • Page 4: Introduction

    The Radio Receiver Card (RC2) acts as a special line card in the system – it receives encoded messages The ENIGMA II DR-81000 stores all events with time from an UHF radio (440..450MHz). The RC2 Card and date stamped. All information is displayed on the...
  • Page 5: System Overview

    ENIGMA II DR-81000 Digital Receiver Version 2.00 System Overview Ademco Contact ID format Up to 8 lines per receiver Ademco SuperFast or High Speed format with or Radio receiver – 2 channels (UHF 440..450MHz) without parity 2000-event non-volatile event buffer in the CPM2...
  • Page 6: Quick Start

    Please, refer to the following chapters of this manual to help you through the installation and operation of Reception of Extended formats is disabled the ENIGMA II DR-81000 digital receiver. Two Way Audio (listen in) is disabled The default setting for serial ports is 9600,8,N,1 Chapter 3.
  • Page 7: Installation

    Computer Connections 3. Installation Connect the automation computer to the ENIGMA II DR-81000 serial COM A port using the supplied Mounting the Receiver cable. If the supplied cable is not long enough, a The ENIGMA II DR-81000 receiver is shipped by serial Null-modem cable can be used up to 15 meters default in a standard 3HE 19”...
  • Page 8: Telephone Line Connections

    ENIGMA II DR-81000 Digital Receiver Version 2.00 Telephone Line Connections Grounding Connect the telephone lines to the Line Cards LINE To achieve the best resistance against static and modular jack with RJ11 4/6 pin modular cables. For electric noise and electromagnetic interference (EMI)
  • Page 9: Power Supply Card

    ENIGMA II DR-81000 Digital Receiver Version 2.00 Power Supply Card It is very important to connect protective ground The Power Supply of the receiver is housed in the (shielding) to the grounding terminal on the back of Power Card. The Power Supply requires 16.5 VAC the PWR card.
  • Page 10: Removing And Installing Cards

    ENIGMA II DR-81000 Digital Receiver Version 2.00 Removing and Installing Cards Install the LCM backplane to the extension subrack The receiver does not have to be powered down Remove the top cover of the desktop housing while components of the system are removed or installed.
  • Page 11: The Enigma Ii Controls

    ENIGMA II DR-81000 Digital Receiver Version 2.00 1..8 LEDs 4. The ENIGMA II Controls The LEDs 1..8 display status information of the line cards. Continuous green light indicates standby mode – the line is ok, and the card is waiting for call.
  • Page 12: Cpm2 Card

    CPM finds an error during the self test it will stop, The CPM2 Card is the central processing Card of the beeping and the problem will be displayed on the ENIGMA II DR-81000 that controls the line cards and LCD. forwards the information from the line cards to the printer and the central station computer.
  • Page 13: The Status Row

    ENIGMA II DR-81000 Digital Receiver Version 2.00 The Status Row The status row is the topmost row of the LCD display. The fourth column contains the time of the event. It shows pending receiver problems and system Every event, including the service and trouble events messages.
  • Page 14: Protected Mode Operation

    ENIGMA II DR-81000 Digital Receiver Version 2.00 Protected Mode Operation The password can be entered with the function keys In protected mode, the receiver is operating the same a similar way as it is well known and used to with way as in normal mode, except that all the menu and mobile phones.
  • Page 15: The Menu

    ENIGMA II DR-81000 Digital Receiver Version 2.00 The Menu The Enigma II has a context-sensitive menu system. The menu is displayed on the bottom of the screen, the items (functions) can be activated by pressing the Function keys below them.
  • Page 16: Time & Date

    ENIGMA II DR-81000 Digital Receiver Version 2.00 decreased with the – (F2) button. Pressing a button continuously will repeat the action until the button is The default setting is A OR B, so that if any of the released. After the fields are set correctly, press the ports is connected to the PC, the link will be Enter key to save the set values.
  • Page 17: Cpm2 Ports

    Version 2.00 CPM2 Ports If the automation software is not compatible with The ENIGMA II DR-81000 digital receiver is equipped heart-beat supervision, the heart-beat signals can with two RS232 serial ports, one Centronics parallel also be turned off (See Port Options).
  • Page 18 ENIGMA II DR-81000 Digital Receiver Version 2.00 independently. However, as their operation is The default setting is Compatible Mode. For detailed identical, their parameters are set similarly. specifications of Compatible Serial Protocols, please, refer to the Serial Protocols section. Port Settings Here the asynchronous protocol for the serial port is set –...
  • Page 19: Serial Protocols

    ENIGMA II DR-81000 Digital Receiver Version 2.00 Serial Protocols SIA Level 1 Protocol The SIA Level 1 Protocol is used to forward events The receiver uses different serial communication protocols for the connection to the automation received in SIA format. When multiple events are received in one SIA data block (SIA level 2 and 3), software on the central station computer.
  • Page 20: Serial Port Status Display

    ENIGMA II DR-81000 Digital Receiver Version 2.00 Ademco High-Speed Protocol Clock Signal Protocol This protocol is used to transmit events received in The Clock Signal Protocol is used to transmit time the Ademco High-Speed (4/8/1) format. and date information together with the events. The...
  • Page 21: Usb Port

    Now, browse for the driver. If you have already This port is linked internally with the COM B port, so installed the Enigma II programmer software, the that only one of them can be used at a time. driver can be found in the “C:\Program Files\ENIGMA II\UsbDriver”...
  • Page 22: Parallel Port

    The CPM Unit has a 8-bit parallel port for printer More about the settings and options of the optional connection. Practically any printer with Centronics Ethernet interface can be found in the “Enigma II parallel interface can be connected to the port, and TCP/IP Interface Manual”...
  • Page 23: Lc2 Line Card

    Up to 8 LC2 Line Cards can be installed in the the digital communicators of the control panels and Enigma II receiver. The installation procedure of the the CPM2. Different communication formats can be Line Cards is described in Chapter 3.
  • Page 24: Line Card Controls

    ENIGMA II DR-81000 Digital Receiver Version 2.00 Line Card Controls Stand-by Mode The Line Cards do not have dedicated external After power-up or reset, the LC2 line card performs a controls except for their status LEDs. The control of short self-test, then it goes to stand-by mode. In...
  • Page 25: Call Reception

    ENIGMA II DR-81000 Digital Receiver Version 2.00 message will be sent to the CPM. The type of faults Call Reception can be the following: When a call is received, the Line Card first indicates the ringing on the phone Line...
  • Page 26: Caller Id Processing

    ENIGMA II DR-81000 Digital Receiver Version 2.00 terminate the call at any time by pressing the “HANG Operating in Stand-alone Mode UP” (F4) button of the context-menu. The Line Card If the CPM2 fails to poll the Line Cards, or...
  • Page 27: Hang Up

    ENIGMA II DR-81000 Digital Receiver Version 2.00 Hang Up Note: When using VOIP connection with analog line The last item of the line card context-menu can be interface as the telephone line connection for the used to hang up the ongoing communications at any receiver, the control signals on call termination may time.
  • Page 28 ENIGMA II DR-81000 Digital Receiver Version 2.00 SIA Timing The second two values define the event code range, The timings of SIA communication are to be set here. that will activate the 2-way audio for the line card. For The first value is the length of the SIA handshake in example: 10 millisecond units.
  • Page 29: Line Card Status

    ENIGMA II DR-81000 Digital Receiver Version 2.00 Line Card Status At the Line Card Status screen, it is possible to reset Pressing the “STATUS” button in the Line Card Menu invokes the status display of the selected line card. the selected line card by pressing the “RESET” (F3) button.
  • Page 30: Power Card

    (1.2Ah) recharge the connected battery. If the LED blinks batteries will not be found good. The recommended fast, it indicates a problem of the power supply. battery capacity for the ENIGMA II receiver is 7 Ah.
  • Page 31: Appendices

    ENIGMA II DR-81000 Digital Receiver Version 2.00 Appendices Appendix A: System Event Table (0000) Message Code Description No AC power AC ERROR AC RESTORED The AC power has been restored BATTERY LOW No battery, or not properly charged Battery is ok...
  • Page 32: Appendix B: Supported Communication Formats

    ENIGMA II DR-81000 Digital Receiver Version 2.00 Appendix B: Supported Communication Formats Name Data Speed Format Ext. Kissoff Ademco Slow 1400 Hz 1900 Hz pulse 10 bps 3/1, 3/2, 4/1, 4/2 1400 Hz Silent Knight Fast 1400 Hz 1900 Hz pulse 14 bps 3/1, 3/2, 4/1, 4/2...
  • Page 33: Appendix C: Trouble Shooting Guide

    ENIGMA II DR-81000 Digital Receiver Version 2.00 Appendix C: Trouble Shooting Guide Problem: No communication with the central station computer on COM A Solution: Ensure that the cable used is a Null Modem cable and connected properly. Check the serial port configuration of the receiver and the computer.

Table of Contents