Program The Communications Module - Honeywell LYNX Touch Series Installation And Setup Manual

Lynx touch series
Hide thumbs Also See for LYNX Touch Series:
Table of Contents

Advertisement

LYNX Touch Installation and Setup Guide
Programming the Control

Program the Communications Module

The following system options are programmed in this section:
Option
Communications Path
Primary City Id
Primary Central Station Id
Primary Subscriber Id
Supervision
Old Alarm Time
Remote Acc. IP or GSM
Multi Mode IP or GSM
IP Fault Time
Use DHCP
NIC IP Address
Subnet Mask
Gateway IP Address
DNS Server IP Address
GSM Fault Time
GSM Rollover
GSM 24 Hour Test
Note: If applicable, preprogrammed defaults for the LYNX Touch Control are shown on the screen unless otherwise noted.
Remote Access (Total Connect) and Multi Mode (PSD) over IP or GSM cannot be enabled in the panel alone.
Availability of this service is controlled via the web-based programming tool on the AlarmNet Direct website. These
features must to be enabled through the AlarmNet Direct website first and transferred to the device.
SCREEN
Communicator
5000-100-132-V0
Communications Path
None
Primary City Id
Pri Central Station Id
Primary Subscriber Id
Selects type of Communications Module
Enter Central Station Primary City ID
Enter Primary Central Station ID
Enter Central Station Primary Subscriber ID
Selects how often the Communications Module sends a supervisory message to the Central
Station.
Selects how long an undeliverable alarm delivery is retried to the Central Station.
Enables or disables user remote access via internet and/or GSM.
(appears only if Remote Access IP or GSM is enabled.) Enables or disables multi mode
feature.
(Appears only if IP is enabled in Communications Path field.) Selects time delay before the
Communications Module notifies the control panel of a loss of contact with the internet.
Dynamically selects the IP addresses
(Appears only if "No" is selected in Use DHCP field.) Enter NIC IP Address.
(Appears only if "No" is selected in Use DHCP field.) Enter Subnet Address.
(Appears only if "No" is selected in Use DHCP field.) Enter Gateway IP Address
(Appears only if "No" is selected in Use DHCP field.) Enter Domain Name Server IP
Address.
(Appears only if GSM is enabled in Communications Path field.) Selects time delay before
the Communications Module notifies the control panel of a loss of contact with the network.
Allows messages to be sent over GSM in the event that contact with the internet is lost.
Enables daily test of GSM module operation.
Communicator
1.
Select "Communicator"
The System displays the following options:
Communications Path
Pri Central Station Id
Supervision
Remote Acc. IP or GSM
Use the down
GSM Fault Time
OR
IP Fault Time
2.
Select "Communications Path". The system scrolls between the following options:
None
IP
GSM
3.
Select "Primary City Id". Enter the 2-digit Primary City ID (Decimal).
Options
01-99
4.
Select "Pri Central Station Id". Enter the 2-digit Primary Central Station ID (HEX).
Options
01-FE
5.
Select "Primary Subscriber Id". Enter the 4-digit Subscriber Account Number
(Decimal).
Options
0001-9999
WWW.DIYALARMFORUM.COM
Function
ACTION
Primary City Id
Primary Subscriber Id
Old Alarm Time
Multi Mode IP or GSM
arrow to scroll to the next page of options.