Installing the ILP5 in the LYNX Touch Control
Ensure that the connector board and cable are securely installed in the ILP5 before installing the
communications module in the LYNX Touch.
1.
Using a wire cutter or knife cut the plastic tabs that secure the ILP5 spacer from to the back case of the LYNX Touch.
2.
Remove the ILP5 receptacle knockout from the left side of the LYNX Touch back case.
3.
Install the ILP5 into the LYNX Touch control front case. Ensure that the connector board is properly seated into the receptacle on the
control.
4.
Secure the ILP5 with the three provided screws.
5.
Insert the ILP5 receptacle and spacer into the slot on the back case.
6.
Secure the communications cable to the tie wrap point on the ILP5 with the provided tie wrap.
7.
Connect the Ethernet cable to the RJ45 receptacle.
8.
Enable the ILP5 and configure alarm reporting and module supervision and register the device. Refer to the "Program the
Communications Module" and "Communications Diagnostics" sections.
Alternate Installation (Refer to the Alternate Installation as shown on the figure below)
1.
Install the ILP5 into the LYNX Touch control front case. Ensure that the connector board is properly seated into the receptacle on the
control.
2.
Secure the ILP5 with the three provided screws.
3.
Insert the ILP5 receptacle into the slot on the back case as shown on the figure below.
4.
Secure the communications cable to the tie wrap point on the ILP5 with the provided tie wrap.
5.
Connect the Ethernet cable to the RJ45 receptacle.
6.
Enable the ILP5 and configure alarm reporting and module supervision and register the device. Refer to the "Program the
Communications Module" and "Communications "Diagnostics" sections.
The communications module must be registered with AlarmNet before downloading or alarm reporting
can take place.
TO ILP5
RJ45 RECEPTACLE
LYNX TOUCH
ALTERNATE INSTALLATION
CONNECTOR
BOARD
CONNECTOR BOARD
SCREW
(3)
WWW.DIYALARMFORUM.COM
Installing/Configuring Communication Modules
ETHERNET CABLE
ILP5 SPACER
RJ45
RECEPTACLE
ROTATED
TIE
180
WRAP
(1)
TIE
WRAP
POINT
ILP5
RECEPTACLE
LYNX TOUCH
LYNX Touch Installation and Setup Guide
REMOVE ILP5
REMOVE ILP5
KNOCKOUT