Honeywell LYNX Touch Series Installation And Setup Manual page 14

Lynx touch series
Hide thumbs Also See for LYNX Touch Series:
Table of Contents

Advertisement

LYNX Touch Installation and Setup Guide
Installing Wireless Zones
5800 Series Transmitter Loop Numbers
(Refer to this information when programming transmitters)
The following illustration shows the compatible transmitters, their associated input types and loop
designations.
LOOP
1
LOOP
1
5 8 0 0 C O
5 8 0 0 M i c r a
E N R O L L A S " R F "
E N R O L L A S " R F "
LOOP
1
LOOP
1
5 8 0 0 S S 1
5 8 0 0 WAV E
E N RO L L A S " R F "
P RO G R A M
H O U S E I D
SERIAL #1
LOOP 3
SERIAL #1
O N
LOOP 2
O F
F
SERIAL #1
1
2
LOOP 4
SERIAL #1
3
LOOP 1
SERIAL #2
4
LOOP 3
SERIAL #2
LOOP 2
SERIAL #2 - LOOP 1 = ON + 4 BUTTONS
LOOP 4 = 3 + 4 BUTTONS
5 8 0 5 - 6
5808/5808LST/5808W3
ENROLL AS "BR"
LOOP 2
(REED)
LOOP 1
(TERMINALS)
ALTERNATE
POSITION
FOR LOOP 2
5 8 1 6 T E M P
5 8 1 6 M N
ENROLL AS "RF"
ENROLL AS "RF"
AR
M ED
R EA
D Y
LOOPS
1 - 3
5 8 2 8 / 5 8 2 8 V
5 8 2 1
P RO G R A M
ENROLL AS "RF"
HOUSE ID
LOOP 1
(MOTION)
LOOP 1
5 8 9 0 / 5 8 9 0 P I
5 8 9 4 P I
ENROLL AS "RF"
ENROLL AS "RF"
Notes: (1) The 5806W3 smoke detector must be used in SIA applications.
(2) Button type (BR) devices send only fault and low battery signals; no restore or check-in signals.
Supervised RF (RF) devices send periodic check-in signals, faults, restore and low battery signals.
Unsupervised RF (UR) devices send periodic check-in signals, faults, restore and low battery signals but the
control does not supervise the check-in signals.
(3) If an external sounder is required, the 5800WAVE should be used.
UL
The 5800RL, 5802MN, 5802MN2, 5804, 5804BD, 5804BDV, 5814, 5816TEMP, 5819, 5819S(WHS & BRS), and
5828/5828V wireless transmitters
LOOP 1
5 8 0 0 P I R - R E S
E N R O L L A S " R F "
LOOP 1
5 8 0 2 M N
ENROLL AS
"UR" OR "RF"
LOOP 1
5806/5806W3/5807
5809
ENROLL AS "RF"
ENROLL AS "RF"
LOOP 1
(PRIMARY)
LOOP 2
(AUX.
CENTER)
LOOP 1
(TEMP
LOOP 3
SENSOR)
(AUX.
RIGHT)
5 8 1 7
ENROLL AS "RF"
ENROLL AS "RF"
SERIAL #2
LOOP 1
SERIAL #1
LOOP 3
SERIAL #1
LOOP 2
SERIAL #2
LOOP 3
SERIAL #2
LOOP 4
SERIAL #1
LOOP 4
SERIAL #1
LOOP 1
SERIAL #2
LOOP 2
5834-4
ENROLL AS "BR"
LOOP 1
5897
ENROLL AS "RF"
have not been evaluated by UL
WWW.DIYALARMFORUM.COM
LOOP 1
(LOW
SENSITIVITY
LOOP 2
(HIGH
SENSITIVITY)
LOOP 3 (TEMP)
LOOP 4 (TAMPER)
5 8 0 0 P I R /
5 8 0 0 P I R - O D
5 8 0 0 P I R - C O M
E N R O L L A S " R F "
E N R O L L A S " R F "
O N
LOOP 4
O F
F
LOOP 1
5 8 0 2 M N 2
5804/5804E
ENROLL AS "BR"
ENROLL AS
"UR" OR "RF"
LOOP 1
LOOP 1
LOOP 1
5 8 1 1
E N R O L L A S " R F "
LOOP 2
(REED)
LOOP 3
LOOP 1
(TERMINALS)
LOOP 1
(TERMINALS)
5 8 1 8
5 8 1 9
ENROLL AS "RF"
LOOP 1
(HIGH
SECURITY)
LOOP 1
LOOP 2
(STANDARD
SECURITY)
LOOP 3 (TILT MODE)
5 8 5 3
5870API
LOOP 4 (TAMPER)
ENROLL AS "RF"
ENROLL AS "RF"
LOOP 1
(LOW SENSITIVITY)
LOOP 2
(HIGH SENSITIVITY)
5 8 9 8
ENROLL AS "RF"
.
- 14 -
LOOP 1
(LOW
SENSITIVITY
LOOP 2
(HIGH
SENSITIVITY)
LOOP 3 (TEMP)
LOOP 4 (TAMPER)
5 8 0 0 R L
S E T
H O U S E I D
LOOP 3
LOOP 2
LOOP 2
LOOP 4
LOOP 1
LOOP
LOOP 1
3
• •
•• •
• • ••
• •
5 8 0 4 B D / 5 8 0 4 B DV
ENROLL AS "BR"
PROGRAM HOUSE ID
LOOP 2
(REED)
LOOP 1
(TERMINALS)
5814
5 8 1 6
ENROLL
ENROLL AS "RF"
AS "RF"
LOOP 2
(REED)
LOOP 3
LOOP 1
(TERMINALS)
LOOP 1
(INTERNAL
SHOCK
SENSOR
5 8 1 9 S ( W H S & B R S )
5 8 2 0 L
ENROLL AS "RF"
ENROLL AS "RF"
SERIAL #1
LOOP 3
SERIAL #1
A W
A Y
LOOP 2
SERIAL #1
S T
A Y
LOOP 4
1
2
SERIAL #1
SERIAL #2
3
LOOP 1
LOOP 3
4
SERIAL #2
LOOP 2
5 8 7 8
ENROLL AS "BR"

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents