1.
Make Earth Ground Connection - The designated earth ground
terminal EGND must be terminated in a good earth ground for the
lightning transient protective devices in this product to be effective.
The following are examples of good earth grounds available at
most installations:
Metal Cold Water Pipe - Secure a non-corrosive metal strap
(copper is recommended) to the pipe that is electrically connected
and secured to which the ground lead is electrically connected and
secured.
AC Power Outlet Ground - Available from 3-prong, 120VAC power
outlets only. To test the integrity of the ground terminal, use a three-
wire circuit tester with neon lamp indicators, such as the UL Listed
Ideal Model 61-035, or equivalent, available at most electrical
supply stores.
a.
Connect terminal EGND to a good earth ground as shown on the
Summary of Connections.
2.
Make Phone Line Connections - For local or full line seizure
follow the appropriate steps below.
Local Seizure
a.
Connect the incoming phone line to either the 8 position jack or
terminals TIP and RING on the LYNX Touch as shown on the
Summary of Connections.
b.
Connect the handset phone lines to terminals H/S T (TIP) and
H/S R (RING) as shown on the Summary of Connections.
terminals as shown in the diagram or plug into the 8-position
Full Line Seizure: The control must be placed in series with the
incoming phone line. Plugging the Direct Connect Cord directly into
the RJ31X jack, allows the control to seize the phone line when an
alarm occurs and normal phone line usage by the premises
phones if the plug needs to be removed.
c.
Cut the incoming RING and TIP phone lines (typically red and
green, respectively) and connect them to RJ31X terminals 4
(red) and 5 (green).
d.
Connect the premises end of the cut RING and TIP wires to
RJ31X terminals 1 (grey) and 8 (brown) respectively.
e.
Wire the flying leads of a Direct Connect Cord to the control's
phone terminals as shown in the diagram or plug into the 8-
position jack.
f.
Plug the Direct Connect Cord into the RJ31X jack.
HARDWIRED ZONE: If the EOLR is not at the end of the
loop, the zone will not be properly supervised, and the
system may not respond to an open circuit on the zone.
Hardwired Zone Connections - One EOLR supervised zone
3.
supports both open circuit and closed circuit devices and has a
response time of 350msec. Maximum zone resistance: 300 ohms,
plus EOLR
Note: The hardwire zone cannot be used as a fire zone.
a.
Connect sensors/contacts to the hardwired zone terminals GND
(-) and HWZ1 (+). Refer to the Summary of Connections
diagram.
b.
Connect closed circuit devices in series in the high (+) side of
the loop. The EOL resistor must be connected in series with the
devices, following the last device.
c.
Connect open circuit devices in parallel across the loop. The
2000-ohm EOLR must be connected across the loop at the last
device.
4.
AC Power Connections - Connect the Power Supply to the
receptacle on the LYNX Touch.
OR
Connect wires from the Power Supply to +9VDC and EGND
terminals as shown on the summary of connections diagram.
WWW.DIYALARMFORUM.COM
LYNX Touch Installation and Setup Guide
RED
4
3
RJ31X
2
1
GREY
OR
OR
TO
INCOMING
PHONE LINE
PREMISES
PHONES
FULL LINE SEIZURE CONNECTIONS
WIRING TABLE
DISTANCE BETWEEN
POWER SUPPLY AND CONTROL
Up to 75 feet
75 to 150 feet
- 7 -

Wiring Connections

INCOMING
PHONE LINE
RING
TIP
GREEN
5
6
TO
PREMISES PHONES
RING
TIP
7
BROWN
8
DIRECT
CONNECT
CORD
8-POSITION
JACK
WIRE
GAUGE
# 20
# 18
5000-100-094-V1