Installing/Configuring Communication Modules

General

This LYNX Touch control supports central station reporting using wireless (GSM) and hardwire (IP)
communications modules. It also supports upload/download programming capability via the Internet or a
Private local area network (Intranet). This allows site maintenance independent of central station
monitoring, and modification to sites globally via the Internet or through a private LAN. Refer to the
instructions provided with the LRR/IP Communications Module being installed for additional information
regarding its installation, programming, and registration. The control is compatible with the following
AlarmNet Communications Modules:
GSMVLP5 GSM Communication Module
ILP5 Ethernet Communications Module
Communications Module 24-Hour Standby Power
If you require 24-hour standby, you must install the Super High Capacity battery P/N LYNX-RCHB-SHA in
the control.

WARNING: The LYNX Touch must be installed to provide a separation distance of at least 7.8 in (20 cm)
from all persons and not co-located or operated in conjunction with any other transmitter.
Connecting and Configuring Communication Modules
Connect and configure the communications module as follows:
Installing the GSMVLP5 in the LYNX Touch Control
Ensure that SIM card and the connector board are securely installed in the GSMVLP5 before installing the
communications module in the LYNX Touch.
1.
Install the GSMVLP5 into the LYNX Touch control front case. Ensure that the connector board is properly seated into the receptacle on
the control.
2.
Secure the GSMVLP5 with the three provided screws.
3.
Enable the GSMVLP5 device, configure alarm reporting and module supervision and register the device. Refer to the "Program the
Communications Module" and "Communications Diagnostics" sections.
The communications module must be registered with AlarmNet before downloading or alarm reporting can
take place.
CONNECTOR
BOARD
ROTATED
180
GSMVLP5
SCREW
3
CONNECTOR
BOARD
SIM
CARD
RECEPTACLE
LYNX TOUCH
WWW.DIYALARMFORUM.COM
RF Exposure
- 10 -
5000-100-151-V0