Sealed System

Definitions

Recovery:
To remove refrigerant in any condition from a system
and store it in an external container without necessarily
testing or processing it in any way.
Recycling:
To clean refrigerant for reuse by oil separation and sin-
gle or multiple passes through devices, such as replace-
able core filter-driers, which reduce moisture, acidity and
particulate matter. This term usually applies to
procedures implemented at the field job site or at a
local service shop.
Reclaim:
To reprocess refrigerant to new product specifications
by means which may include distillation, will require
chemical analysis of the refrigerant to determine that
appropriate product specifications are met. This term
usually implies the use of processes or procedures
available only at a reprocessing or manufacturing facility.
Equipment Needed for
Evacuation & Recharging
1.
1 - Heated Dial-A-Charge charging cylinders.
2.
1 - Recovery/Recycling equipment.
3.
1- Tank for each type of refrigerant you use in
service. (Do not mix refrigerants in the same tank)
4.
1 - External vacuum pumps.
5.
Process tube adapter kit (Robinair No.12458)
6.
Tubing cutter.
7.
Pinch-off tool capable of making leak proof seal.
8.
Leak detector.
9.
Complete brazing torch set.
10. Small 3-corner file.
11. Grit cloth or Scotch-Brite.
12. 45% silver solder and flux.
13. 1 -Gauge and Manifold set. (See Figure 7-1)
14. 2 - Tube piercing valves.
15. Oil test kits.
16. Heat Gun.
17. Swag Tool. (See Figure 7-2)
7-4
Figure 7-1.
Figure 7-2.