Ice Chute Extension

Dispenser Models
The extension on the ice chute is used to better direct
crushed and cube ice into a glass or container. To
replace the chute:
1.
Turn water off to refrigerator.
2.
Push straight back on the extension to release the
rear tabs. (See Figure 6-5)
3.
Pull straight down and tip out of dispenser housing.
4.
Reinstall in reverse order.
Control Assembly Removal
Non-Dispenser Models
Before servicing any part of the control system, the prod-
uct must be unplugged, the fuse pulled or circuit breaker
turned off to prevent damage to the product control sys-
tem or personal injury to the servicer.
When handling and or replacing a control board it is
important the a technician have a wrist ground strap on
and connected to the cabinet or another grounding posi-
tion to prevent static electricity from damaging the board.
To replace the user interface on non-dispenser models:
1. Open the left food door.
2. Place a putty knife between the top of the Express-
Select
touch control and the door panel. Use the
TM
putty knife to slide the top of the control out of the
door panel. (See Figure 6-6)
3. Slide the control out from the top and lift it out of the
door.
4. Disconnect the single harness connector at the top of
the control board.
5. With the control out of the door, remove the board
from the touch control. Disconnect the ribbon connec-
tor at the bottom of the control. (See Figure 6-7)
6. Push out on the 6 retainer tabs, one at a time, start-
ing from the bottom of the board and lift the board up
past the retainer. This will allow removal of the control
board from the touch panel.
To reassemble:
1. Place the board over the touch control housing. Press
the board past the retainers, one at a time, starting at
the top.
2. Reconnect the ribbon connector.
3. Reconnect the door harness to the board.
4. Place bottom of board into the housing in the door.
NOTE: Use caution not to damage the ribbon connector.
5. Push the control into place starting at the bottom and
working up.
Component Teardown
Disconnect
6-3
Figure 6-5.
Insert Putty
Knife
Figure 6-6.
Figure 6-7.