Frigidaire LGUB2642LF2 Service Manual page 57

Bottom freezer refrigerator
Hide thumbs Also See for LGUB2642LF2:
Table of Contents

Advertisement

Ice Maker (Finger Evaporator Fresh Food Compartment)
After pushing 'power on-off' to start automatic test or
turn on the load, the ice maker control will display the
test result on the freezer two digit display. When waiting
for the test to be automatically performed and the result
displayed, the test number (test ID) will flash on/off. After
the automatic test is completed the test result will be
displayed as "P" – pass, or "F" – Fail.
For an interactive test, the technician manually activates
the load using 'power on-off' and physically verifies the
system response. Pressing 'power on-off' again turns
the load off. The freezer display shows the current or
expected state of the load. During the load transition the
fresh food display flashes the test ID. After the last test
step in the ice maker test sequence is completed, the next
advancing action will scroll back around to the first ice
maker test. Stepping back from the first test, will scroll the
test sequence backwards to the last test in the sequence.
Service Diagnostic Mode Test
Sequence
Test 40C: Mold Heater Failure Error
(See Flow Chart Test # 54 C)
The mold heater failure is saved by ice maker and the
Freezer display will show "E1" when the test is entered.
If no error present, the display shows "1".
Test 41C: Harvest Heater Failure Error
(See Flow Chart Test # 56 C)
The harvest heater failure is saved by ice maker and the
Freezer display will show "E2" when the test is entered.
If no error present, the display shows "1".
Test 42C: Bail Arm Switch Failure Error
(See Flow Chart Test # 58 C)
The bail arm switch failure is saved by ice maker and the
Freezer display will show "E3" when the test is entered.
If no error present, the display shows "1".
Test 43C: HV Motor Stuck in Fill Error
(See Flow Chart Test # 63 C)
The harvest motor failure to move from Fill to Freeze is
saved by ice maker and the Freezer display will show
"E4" when the test is entered. If no error present, the
display shows "1".
Prior to sealed system evacuation, the service technician
needs to open the ice maker EEV and then power down
the system (unplug refrigerator's AC power cable). The
valve will close automatically on system (POR) when the ice
maker is turned "ON" and the system AC power is restored.
The POR sequence is followed and, if needed, the reentry
back into the diagnostic mode can be performed.
Temperature Resistance Chart
For Negative Temperature
Coefficient Thermistors
31