Firmware On Replacement Boards And Assemblies; Switzerland Caution - Sun Microsystems Fire E6900 Systems Service Manual

Servers
Hide thumbs Also See for Fire E6900 Systems:
Table of Contents

Advertisement

1.3.4
Firmware On Replacement Boards and
Assemblies
After installing a board or assembly, use the showboards -p proms command to
determine if the firmware needs to be updated. If an update is required, use either
the system controller flashupdate -f or flashupdate -c command. Refer to
the Sun Fire 6800/4810/4800/3800 System Controller Command Reference Manual for
correct usage of the flashupdate command.
Note – Do not use the flashupdate -u command as shown in onscreen messages.
Using flashupdate -u can result in incompatibility issues that require a reboot of
the system controller and domains.
You can find a list of the most current patches for bug fixes and system firmware
upgrade on SunSolve Online
patches, including Year 2000 patches, to all users. Other product and OS patches are
available to SunSpectrum
Care Center or your service provider if you need assistance in accessing the list of
current patches and system firmware upgrades.
1.3.5

Switzerland Caution

Caution – The Sun Fire Sun Fire 3800 system exceeds the rating requirements in
Switzerland for pluggable type A equipment. To comply with national requirements,
customers in Switzerland who receive a standalone Sun Fire Sun Fire 3800 system
(shipped without a rack) must provide a means to connect the system to a pluggable
type B power circuit.
1-4
Sun Fire E6900/E4900 Systems Service Manual • May 2006
sm
. SunSolve provides recommended and security
sm
contract customers. Contact your local Sun Customer

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sun fire e4900

Table of Contents