P1000[0] Selection Of Frequency - Siemens SINAMICS V20 Inverter Getting Started

Hide thumbs Also See for SINAMICS V20 Inverter:
Table of Contents

Advertisement

Parameter list
Parameter
Description
P0775[0]
Permit absolute value
P0777[0]
Value x1 of analog output scaling [%]
P0778[0]
Value y1 of analog output scaling
P0779[0]
Value x2 of analog output scaling [%]
P0780[0]
Value y2 of analog output scaling
P0781[0]
Width of analog output deadband
r0785.0
CO / BO: Status word of analog output
P0809[0...2]
Copy command data set (CDS)
Index:
[0]
[1]
[2]
P0810
BI: command data set bit 0 (Hand / Auto)
P0811
BI: command data set bit 1
P0819[0...2]
Copy inverter data set (DDS)
Index:
[0]
[1]
[2]
P0927
Parameter changeable via
r0947[0...63]
CO: Last fault code
P0970
Factory reset
0
1
21
P1000[0...2]
Selection of frequency setpoint
0
1
2
3
5
7
10
11
12
13
15
17
20
21
22
23
25
27
52
Copy from CDS
Copy to CDS
Start copy
Copy from DDS
Copy to DDS
Start copy
Disabled
Parameter reset
User Default Parameter Reset
No main setpoint
MOP setpoint
Analog setpoint
Fixed frequency
USS on RS485
Analog setpoint 2
No main setpoint + MOP setpoint
MOP setpoint + MOP setpoint
Analog setpoint + MOP setpoint
Fixed frequency + MOP setpoint
USS on RS485 + MOP setpoint
Analog setpoint 2 + MOP setpoint
No main setpoint + Analog setpoint
MOP setpoint + Analog setpoint
Analog setpoint + Analog setpoint
Fixed frequency + Analog setpoint
USS on RS485 + Analog setpoint
Analog setpoint 2 + Analog setpoint
Range
Factory default
0 - 65535
0
-99999 - 99999
0.0
0 - 20
0
-99999 - 99999
100.0
0 - 20
20
0 - 20
0
-
-
0 - 2
[0] 0 [1] 1 [2] 0
-
0
-
0
0 - 2
[0] 0 [1] 1 [2] 0
-
1111 bin
-
-
0 - 21
0
0 - 77
1
30
No main setpoint + Fixed frequency
31
MOP setpoint + Fixed frequency
32
Analog setpoint + Fixed frequency
33
Fixed frequency + Fixed frequency
35
USS on RS485 + Fixed frequency
37
Analog setpoint 2 + Fixed frequency
50
No main setpoint + USS on RS485
51
MOP setpoint + USS on RS485
52
Analog setpoint + USS on RS485
53
Fixed frequency + USS on RS485
55
USS on RS485 + USS on RS485
57
Analog setpoint 2 + USS on RS485
70
No main setpoint + Analog setpoint 2
71
MOP setpoint + Analog setpoint 2
72
Analog setpoint + Analog setpoint 2
73
Fixed frequency + Analog setpoint 2
75
USS on RS485 + Analog setpoint 2
77
Analog setpoint 2 + Analog setpoint 2
Getting Started, 07/2012, A5E03728127
Acc. level
2
2
2
2
2
2
2
2
2
2
2
2
2
1
1
SINAMICS V20 Inverter

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics v20

Table of Contents