Siemens SINAMICS V20 Inverter Getting Started page 46

Hide thumbs Also See for SINAMICS V20 Inverter:
Table of Contents

Advertisement

Commissioning
4.3 Quick commissioning
Parameter
Description
P1080[0]
Minimum frequency
P1120[0]
Ramp-up time
P1121[0]
Ramp-down time
Application macro AP021 - Compressor applications
Parameter
Description
P1300[0]
Control mode
P1080[0]
Minimum frequency
P1312[0]
Starting boost
P1311[0]
Acceleration boost
P1310[0]
Continuous boost
P1120[0]
Ramp-up time
P1121[0]
Ramp-down time
Application macro AP030 - Conveyor applications
Parameter
Description
P1300[0]
Control mode
P1312[0]
Starting boost
P1120[0]
Ramp-up time
P1121[0]
Ramp-down time
46
Factory
Default for
default
AP020
0
20
10
10
10
20
Factory
Default for
default
AP021
0
0
0
10
0
30
0
0
50
50
10
10
10
10
Factory
Default for
default
AP030
0
1
0
30
10
5
10
5
Remarks
Inverter running at a lower speed
inhibited
Ramp-up time from zero to
maximum frequency
Ramp-down time from maximum
frequency to zero
Remarks
Linear V/f
Inverter running at a lower speed
inhibited
Boost only effective when
accelerating for the first time
(standstill)
Boost only effective when
accelerating or braking
Additional boost over the complete
frequency range
Ramp-up time from zero to
maximum frequency
Ramp-down time from maximum
frequency to zero
Remarks
V/f with FCC
Boost only effective when
accelerating for the first time
(standstill)
Ramp-up time from zero to
maximum frequency
Ramp-down time from maximum
frequency to zero