Commissioning
4.3 Quick commissioning
Parameter
Description
P1022[0]
BI: Fixed frequency selection bit 2
P1001[0]
Fixed frequency 1
P1002[0]
Fixed frequency 2
P1003[0]
Fixed frequency 3
P0771[0]
CI: Analog output
P0731[0]
BI: Function of digital output 1
P0732[0]
BI: Function of digital output 2
Connection macro Cn004 - Fixed speeds in binary mode
Fixed speeds with ON command in binary mode
● Up to 16 different fixed frequency values (0 Hz, P1001 ... P1015) can be selected by the
Connection macro settings:
Parameter
Description
P0700[0]
Selection of command source
P1000[0]
Selection of frequency
P0701[0]
Function of digital input 1
P0702[0]
Function of digital input 2
P0703[0]
Function of digital input 3
P0704[0]
Function of digital input 4
P1016[0]
Fixed frequency mode
P0840[0]
BI: ON / OFF1
36
fixed frequency selectors (P1020 ... P1023)
10V AI1 AI2 0V DI1 DI2 DI3 DI4 DIC 24V 0V
0V
AO+ AO- DO1+ DO1-
N
0~20mA=
0~50/60Hz
Factory
Default for
default
Cn003
722.5
722.3
10
10
15
15
25
25
21
21
52.3
52.2
52.7
52.3
DO2
0V
P+ N-
220V
Factory
Default for
default
Cn004
1
2
1
3
0
15
0
16
9
17
15
18
1
2
19.0
1025.0
Remarks
DI4
Speed low
Speed middle
Speed high
Actual frequency
Inverter running
Inverter fault active
M M
OK
OK
Remarks
Terminals as command source
Fixed frequency
Fixed speed bit 0
Fixed speed bit 1
Fixed speed bit 2
Fixed speed bit 3
Binary mode
Inverter starts at the fixed speed
selected
SINAMICS V20 Inverter
Getting Started, 07/2012, A5E03728127