Siemens SINAMICS V20 Inverter Getting Started page 31

Hide thumbs Also See for SINAMICS V20 Inverter:
Table of Contents

Advertisement

Parameter
Access
level
P0307[0] ●
1
P0308[0] ●
1
P0309[0] ●
1
P0310[0] ●
1
P0311[0] ●
1
P1900
2
See also
Parameter list (Page 49)
SINAMICS V20 Inverter
Getting Started, 07/2012, A5E03728127
Function
Rated motor power [kW / hp]
If P0100 = 0 or 2, motor power unit = [kW]
If P0100 = 1, motor power unit = [hp]
Rated motor power factor (cosφ)
Visible only when P0100 = 0 or 2
Rated motor efficiency [%]
Visible only when P0100 = 1
Setting 0 causes internal calculation of value.
Rated motor frequency [Hz]
Rated motor speed [RPM]
Select motor data identification
= 0: Disabled
= 2: Identification of all parameters in standstill
Commissioning
4.3 Quick commissioning
Text menu
(if P8553 = 1)
P0100 = 0 or 2:
(MOT P)
P0100 =1:
(MOT HP)
(M COS)
(M EFF)
(M FREQ)
(M RPM)
(MOT ID)
31

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics v20

Table of Contents