CHAPTER 2 SPECIFICATIONS

All specifications are subject to change without notice.
Contact factory for specific model availability.
1.Rated output voltage
2.Rated Output Current
3.Rated output power
1.Rated output voltage
2.Rated Output Current
3.Rated output power
1. Input voltage/freq.(range)
2.No of phase
3. Dropout voltage
4. Input current 180/360/432Vac
5. Power Factor
6. Efficiency at Low Line,100% load
7. Inrush current
8. Leakage current
9. Input Protection
10. Fuse
11. Input Overvoltage Protection
12. Phase Imbalance
1. Max. line regulation c.v
2. Max. line regulation c.c
3. Max load regulation c.v
4. Max load regulation c.c
5. Temp. drift c.v
6. Temp. drift c.c
7. Stability c.v
8. Stability c.c
9. Output noise p-p(20MHz) c.v
10. Ripple r.m.s 5Hz~1MHz c.v
11. Ripple r.m.s 5Hz~1MHz c.c (10kW)
12. Ripple r.m.s. 5Hz~1MHz c.c (15kW)
*Ripple and Noise at Full Rated Voltage & Load at 25C, Nominal Line. For models not listed use the ripple limit of the next higher voltage model. Per EIJ RC9002A
13. Rem. sense compensation/wire
1. OCP
2. OCP type
3. Knee point protection
4. Short circuit protection
5. Short circuit burn-in
6. Foldback protection
7. Foldback response time
8. OVP type
9. OVP programming accuracy
10. OVP adjustment method
11. OVP trip point
12. OVP response time
13. Max. OVP reset time
14. Output under voltage limit
15. Input under voltage protection
16. Over temp. protection
17. Phase Loss Protection
1. OUTPUT RATING (Duty Cycle Continuous Duty).
1.1 STANDARD MODELS - 10kW
V
7.5
10
12.5
20
25
A
1000 1000
800
500
400
kW
7.5
10.0
10.0
10.0
10.0
1.1 STANDARD MODELS - 15kW
V
N/A
N/A
N/A
N/A
N/A
A
kW
2.INPUT CHARACTERISTICS
V
7.5
10
12.5
20
25
---
208VAC (180-253); 400VAC (360-440); 480VAC (432-528), all 47-63Hz.
---
3 Phase (Wye or Delta) 4 wire total (3 Phase and 1 protective earth ground)
V
175/355/425
A
10kw - 45/23/20
---
0.88 Passive
%
77min for 7.5KW, 83 min for 10kW; 88 min for 15kW
A
Not to exceed full rated Input current See Para. 2.4
mA
3.5 (EN60950-1) max.
---
208 Circuit Breaker, 400/480 - Line Fuse
---
400/480 Input Only
Unit shall not be damaged by line overvoltage with max. duration of 100uSec. Up to 120% of nominal AC input voltage.
%
= < 5% on Three Phase Input
3. STATIC CHARACTERISTICS
V
7.5
10
12.5
20
25
---
0.1% of FS from Io min. to Io max
---
0.1% of FS from Vo min. to Vo max
---
0.1% of FS from Io min. to Io max
---
0.1% of FS from Vo min. to Vo max
---
+/-0.05% of Full Scale Over 8 hours, after 30 minute warm up, constant Line, Load & Temperature
---
+/-0.05% of Full Scale Over 8 hours, after 30 minute warm up, constant Line, Load & Temperature
200 (0.02% Full Scale)/Degree C
PPM/C
300( 0.03% Full Scale)/ Degree C
PPM/C
mV
60
60
60
60
60
mV
20
20
20
20
20
mA
5100 5100
2600
2600 1700 1700
mA
V
1
1
1
1
1
4.PROTECTIVE FUNCTIONS
V
7.5
10
12.5
20
25
%
0~100
---
Constant current
---
None. No damage at knee point operation
---
Yes
---
Yes
---
Output shut down , manual reset by front panel OUT button.
S
Less than 1
---
Inverter shut-down, manual reset by On/Off recycle or by OUT button
%
5% Full Scale
---
Adjust by front panel Voltage encoder and comm port.
V
0.05 to (1.02-1.05) x Rated Output Voltage
mS
Less than 10mS for Output to begin to drop.
S
7 from Turn On.
---
Preset by front panel or communication port. Prevents from adjusting Vout below limit.
Raises the Output good signal in case of output voltage is below limit.
---
Yes. Power supply shut down below low line.
---
Unit shall shut down when internal temperature exceeds safe operating levels. (Latched in Safe mode and
unlatched in auto mode).
Yes
83-530-000 Rev G
30
40
50
60
80
333
250
200
167
125
10.0
10.0
10.0
10.0
10.0
10.0
N/A
N/A
N/A
60
80
250
187.5
15.0
15.0
15.0
30
40
50
60
80
15kW - 64/32/27
All at full rated output power.
30
40
50
60
80
0.01% of FS from lo min. to lo max
0.05% of FS from lo min. to lo max
0.02% of FS lo min. to lo max
0.75% of FS from Vo min. to Vo max
60
60
75
75
100
20
20
20
20
25
100
80
67
50
100
100
1.5
2
3
3
4
30
40
50
60
80
10
100
125
150
200
250
300
100
80
66
50
40
33
10.0
9.9
10.0
10.0
9.9
100
125
150
200
250
300
150
120
100
75
60
50
15.0
15.0
15.0
15.0
15.0
100
125
150
200
250
300
100
125
150
200
250
300
100
125
135
135
200
200
25
25
25
35
35
60
40
32
20
20
16
13
100
50
50
20
20
20
5
5
5
5
5
5
100
125
150
200
250
300
400
500
600
25
20
17
10.0
10.0
10.2
400
500
600
37.5
30
25
15.0
15.0
15.0
400
500
600
400
500
600
200
300
350
60
60
60
10
8
7
10
10
10
5
5
5
400
500
600