Setting the Closed Position Limits
for Pull to Open Applications
TURN CONTROL BOX ON
NOTE:
The OPEN limit is when the opener is fully retracted and the gate is in the full open position. The open limit setting
can only be adjusted by moving the gate bracket. To achieve the optimum closed position, you must adjust the CLOSED
limit setting:
Step 1
Confirm that the power switch is in the ON position, and the gates are in the OPEN POSITIONS.
Step 2
Activate your openers by pressing the entry transmitter
button. Your gates should now be moving from the fully
open positions toward their closing position. Prepare to
STOP gate that reaches the desired closed position first
by pressing the entry transmitter button again. This step
may be repeated until desired close position is achieved.
Once the desired CLOSED position has been achieved,
proceed to step 3.
Step 3
Note which gate has reached the desired closed position
(typically it's the Second gate), program the closed
limit setting by pressing and holding the corresponding
'LEARN MAST LIMIT' or 'LEARN 2ND LIMIT' for 5
seconds.
Step 4
Press the transmitter button and allow the gates to
return to the fully open position. YOUR FIRST
GATE'S CLOSED POSITION LIMIT IS NOW
PROGRAMMED.
Step 5
Activate your openers again by pressing the entry transmitter button. Your gates should now be moving from the fully open
positions toward their closing position. The gate programmed in Step 4 will stop at the spot you just programmed and the
other gate will continue to close until you press the transmitter button again. The optimum CLOSED POSITION for the
second gate is when it closes firmly, without excess tension, against the first gate. This step may be repeated until desired
close position is achieved. Once the desired CLOSED position has been achieved, proceed to step 6.
Step 6
Repeat step 3 for the other gate that has not been set in step 3.
Step 7
Press the transmitter button and allow the gates to return to the fully open position. BOTH YOUR MASTER AND SECOND
GATE'S CLOSED POSITION LIMITS ARE NOW PROGRAMMED.
CLOSE TIME
STALL FORCE
120
MIN
MAX
ART OFF
ON
G
OFF
ON
PULL
PUSH
EN
DLY.
SIMULT.
OFF
ON
OFF
ON
25
STATUS
LEARN RMT
S3
LEARN
MAST LIMIT
S2
LEARN
Learn Master Limit
2ND LIMIT
Button
S4
Learn Second Limit
Button

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Silver-hd dual

Table of Contents