Setting Your Personal Transmitter Code - Mighty Mule Silver-HD Dual 25th annivesary series Installation Manual

25th annivesary series heavy duty
Table of Contents

Advertisement

TESTING YOUR CLOSED LIMIT SETTING:
Press your entry transmitter and allow your gates to close. If CLOSED positions are not correct or need to be changed, you
will need to CLEAR your CLOSED LIMIT settings and follow Steps 1-7 again.
CLEARING PROGRAMMED CLOSED LIMIT SETTING:
If you make a mistake and set the limit at the wrong position – press your transmitter to return the gates to their fully opened
positions, then press and hold the 'LEARN MAST LIMIT' or 'LEARN 2ND LIMIT' button for 5 seconds. This will clear the
memory for the closed limit positions. Follow Steps 1-7 again.

Setting Your Personal Transmitter Code

All GTO transmitters are set to a standard code at the factory and are ready to operate your GTO® Gate Opener
your safety and security, however, we strongly recommend that you replace the factory setting with your own personal code.
Follow the directions below:
1. Remove the Transmitter Cover
On the back of the transmitter use a small phillips head screw driver to remove
the two screws on the sides of the visor clip and separate the front cover from the
transmitter. With the front cover removed, the battery and the DIP switches will
be exposed. To set a new code, use a small screwdriver to move the switches.
2. Set the transmitter DIP Switches
There are nine (9) transmitter DIP switches; each can be placed in three different
positions (+, 0, –). DO NOT set all the switches in the same position, such as all +,
all 0, or all –. Once the DIP switches have been set to a personal code, replace front
cover.
WARNING: No other adjustments should be made inside the transmitter.
3. "Teach" the New Code to Control Board Memory
A. Press and hold transmitter button.
B. Press and hold the LEARN RMT (Learn Remote) button
on the control board until the buzzer sounds.
C. Release transmitter button. The new code
is stored in control board memory.
D. Release the LEARN RMT (Learn Remote) button.
1 2 3 4 5 6 7 8 9
+
0
CLOSE TIME
STALL FORCE
120
MIN
ART OFF
ON
G
OFF
ON
PULL
PUSH
EN
DLY.
SIMULT.
OFF
ON
OFF
ON
26
®
. For
ECE
STATUS
LEARN RMT
MAX
S3
Learn Remote
LEARN
MAST LIMIT
Button
S2
LEARN
2ND LIMIT
S4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Silver-hd dual

Table of Contents