Connnecting Accessories

Input Connections

• All control inputs are dry-contact, normally open, inputs. DO NOT apply external voltage sources to these
inputs.
• All inputs are connected with respect to COMMON terminal.
• The status LED will blink once when any input is activated.
1
COM: Circuit common (reference for all
logic input)
• Two (2) terminals to provide extra
common connection point.
2
CYCLE/CLOSE: (Typically for use with
push button or hard-wired keypad)
• Each activation at this input will cycle
the operation as follows:
OPEN–STOP–CLOSE–STOP–OPEN
3
SAFETY: (Typically for use with photo
beam device, loop detector or other
non-contact sensors)
• Activation of this input while the gate
is closing will cause the gate to stop
and return to the opened position.
• Activation of this input while the gate
is opening has no effect (gate will
continue to open).
• Activation of this input while gate is
idle will prevent gate from closing.
4
EXIT/OPEN: (Typically for use with exit
loop or wand)
• Activation of this input will open the
gate if it's not already at the open
position
• Activation of this input while at open
limit will restart the auto close time (if
enabled).
5
SHADOW LOOP: (Typically for use with loop detector)
• This input is only monitored when the gate is at the fully open position. At any other position, activation of
this input has no effect on gate operation.
• Activation of this input while gate at the fully open position will prevent gate from closing.
6
CLOSE EDGE: (Typically for use with safety edge device)
• Activation of this input while the gate is closing will cause the gate to stop and reverse direction for
approximately 2 seconds.
• Activation of this input while the gate is opening has no effect (gate will continue to open).
• Activation of this input while gate is idle will prevent gate from closing.
7
OPEN EDGE: (Typically for use with safety edge device)
• Activation of this input while the gate is opening will cause the gate to stop and reverse direction for
approximately 2 seconds.
• Activation of this input while the gate is closing has no effect (gate will continue to close).
• Activation of this input while gate is idle will prevent gate from opening.
BLK
1
COM
COM
2
CYCLE
3
SAFETY
4
EXIT
5
SHADOW
CLOSE
6
EDGE
OPEN
7
EDGE
GRN
BLK
RED
28

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Silver-hd dual