INSTALLATION & STARTUP (continued)

Startup Procedure

This Garland 3-platen grill comes
with a factory startup at no
additional charge. A startup is
required to take place BEFORE
the unit is put into operation. It
is the end-user responsibility
to schedule the startup with
their local Factory Authorized
Service Agent, or notify Garland
Commercial Industries at 1-800-
446-8367 should you need
assistance scheduling.
A factory startup is a
comprehensive grill check
in which a factory certified
technician will document all
final settings programmed in
the controller once various
other performance checks
are complete. The estimated
time to complete a startup
is approximately 2.5 – 3.5
hours. Please keep in mind
this estimated time when
scheduling the startup. After
hours or overtime is not covered
under warranty and will be
billed at a charge which is the
difference between the Garland
Reimbursement rate and the
Factory Authorized Service
Centers overtime charges.
A factory startup is necessary
to start the warranty period.
The Authorized Service Center
is required to complete the
paperwork during the startup
process, and send it to Garland
Commercial Industries for
reimbursement. At the time
of receipt, Garland will start
the warranty period which will
conclude at the end of 2 years.
You may contact your Kitchen
Equipment Supplier or dial
1-866-735-1955 for more details
regarding an optional 3rd year
extended warranty plan.
Page 16
All aspects of the Starup procedure must be documented using the Garland-issued
form, part #4521780:
GARLAND CLAMSHELL GRILL START – UP FORM
ELECTRIC OR COMBINATION GAS / ELECTRIC
(FOR USE IN MODEL MWE3W/MWG3W & MWE2W/MWG2W Series grills ONLY)
McDonald's ____________ Certification ID # _________ Store # _____________ Start-up Date ________________________
Located on Certification Sticker
Address _______________________________ City _________________________ Model #
State / Province ____________________________ Zip Code _________________ Serial # _____________________________
United States
Canada
International (List Country) __________________ Telephone # _________________________
Gas Type
Actual Gas Type ____________
Matches Rating Plate?
YES
NO
NOTE: CENTER PLATEN should not be checked if MWE2W / MWG2W
Ensure grill is installed in the proper type of gas exhaust hood with the proper air draw.
1.
2.
Ensure flu restrictors are fully opened or removed.
3.
Ensure bottom plate is leveled side to side / front to back / diagonally, in location, under hood. Adjust casters to attain level.
REMOVE GRILL FROM UNDER THE HOOD. Turn Power Switch ON, controller displays are active, Controller displays "OFF".
4.
All platen raises automatically?
5.
Lower and raise Upper Platen and insure movement is smooth and continuous. Grease shafts accordingly with a FOOD GRADE
LUBRICANT.
6.
If upper platen elevation requires lowered to allow for clearance of hood, lower upper limit switch. Refer to Operations &
Installation manual for platen heights.
7.
Press the POWER ON button. Controller displays "PREHEAT - AM", platen lowers. Heat indicator lights are AMBER?
8.
Press the AM / PM key. This will allow the unit to heat to: Platen-425˚F(217˚C), Grill-350˚F(177˚C).
9.
Grill enters SOAK mode (15:00 timer), counts down and upper platen auto calibrates at temperatures: Platen-425˚F(217˚C), Grill-
350˚F(177˚C)
10. Close valve handle and verify the unit tries to ignite four (4) times. Unit locked out to Ignition Failure?
11. GAS PRESSURE CHECKS (if applicable):
Rated Incoming Pressure
Natural Gas
Propane / Butane Gas
Rated Burner Pressure
Natural Gas
Propane / Butane Gas
12. Check micro amp reading to ensure operating micro amps ARE NO LESS THAN .8. Micro Amp reading should be between .9 –
1.2.
13. Upon Completion of auto calibration, platen raised automatically, and display reads "READY"
If upon completion of auto calibration process, upper platen does not raise, indicate message on controller. Check platen level and adjust
reed switches. Cycle power and retry.
14. Select menu item "10:1 – CLAM". Verify set temperature is reached and LED lights turn GREEN.
15. Initiate cook cycle by pushing the GREEN PUSHBUTTON. Platen lowers, and timing cycle begins.
16. Ensure the stores pyrometer is accurate and calibrated using the ice bath method.
17. Perform PROBE CALIBRATION.
18. Perform Platen Zeroing procedure & Reed Switch Calibration in "LEVEL / REED SW" mode.
19. Platen performed Auto Calibration upon completion of reed switch calibration?
20. Assist or obtain assistance with store personnel for Beef Integrity Testing, testing product 10:1 and 4:1 until desired internal
product temperatures are met.
21. Record cook times, gap settings, and any gap calibrations used to obtain beef integrity.
22. Record Calibration numbers below:
Product Cook Times
(MWE3W & MWG3W | MWE2W & MWG2W)
LEFT
10:1
4:1
ANGUS
2 PLATEN PRC Grills
Front LT
ONLY
LEFT
RIGHT
Problems / Special Circumstances / Damage:
__________________________________________________________________________________________________________________________________
__________________________________________________________________________________________________________________________________
Submitted by:
Name: __________________________________________________
Service Agency: __________________________________________
Sub Agent: (If Applicable) __________________________________
Are you a factory certified technician?
YES / NO
Date of Certification
/ /
White Copy – Factory
GARLAND CLAMSHELL GRILLS WITH PRODUCT RECOGNITION
Circle One
Electric / 3-phase
Actual Input _______________
□ 208 VAC
□ 380 VAC
Line 1
□ 220 VAC
□ 400 VAC
Line 2
□ 230 VAC
□ 415 VAC
□ 240 VAC
Line 3
INSPECTION / OPERATIONAL CHECK
Flue Box Supplied by KES
Flu Restrictors located inside exhaust hood
6 – 14 Inches W.C.
Actual Incoming __________________
11 – 14 Inches W.C.
Actual Incoming __________________
3.5 Inches W.C.
Actual Left ________ Center ________ Right _________
3.5 Inches W.C.
Actual Left ________ Center ________ Right _________
Calibration numbers (from CALIBRATION MENU)
MWE3W & MWG3W ONLY
Back
CENTER
RIGHT
Reed Cal
Reed Cal
If Applicable
LEFT
CENTER
RIGHT
Calibration numbers (from CALIBRATION MENU)
MWE2W & MWG2W ONLY
Back LT
Front RT
Back RT
Front LT
Cal
Cal
Cal
Cal
Detect
Name: __________________________________________________
Are you satisfied with the start-up procedure that has been performed?
Please indicate any comments
__________________________________________________________________
______________________________________________
Yellow Copy – Service Agency
MM
/
DD
/
YY
MWE3W |
MWG3W |
MWE2W |
MWG2W
Record Amps Per Line Each Contactor
Center
Left
Right
If Applicable)
OK
OK
OK
OK
L
OK | C
OK | R
OK
L
OK | C
OK | R
OK
L
OK | C
OK | R
OK
L
OK | C
OK | R
OK
L
OK | C
OK | R
OK
L
OK | C
OK | R
OK
L
OK | C
OK | R
OK
OK -
L /
C /
R
-
L /
C /
R
Check Platen Level
-
L /
C /
R
Check Reed Switch
L
OK | C
OK | R
OK
L
OK | C
OK | R
OK
OK
L
OK | C
OK | R
OK
L
OK | C
OK | R
OK
L
OK | C
OK | R
OK
L
OK | C
OK | R
OK
L
OK | C
OK | R
OK
Front
Back
Front
Zero Cal
Zero Cal
Back LT
Front RT
Back RT
Detect
Detect
Detect
Accepted by:
Pick Copy – Customer
Rev 3 P/N 4521780 W(091609)