PERIODIC INSPECTIONS
148
To keep Gemini in tip-top shape, you should make the following
inspections every six months (under normal use). Expressed
another way, you should "check under the hood" every half-million
lines of printing. Here's what to check:
Maintenance Check List
o
Clean the print head and sensor peripherals
with a soft brush.
o
Check the various screws and make sure they
are tight. If they aren't, tighten them with a
screwdriver.
o
Rotate the platen, and check for possible
damage.
If the platen is worn or uneven,
replace it.
o
Remain alert to "abnormal" operating sounds.
Strange noises can signal strange conditions,
and the earlier you recognize and fix a
problem, the better.
o
Perform Self-Testing and check the movement
of each mechanism.
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •