AIR DUCT REMOVAL

1.
Remove refractory clips from inside top of firebox. Remove side firebox panels
2.
Remove (3) screws securing firebox liner back and baffle to firebox back wall. Remove liner. Pull baffle forward and down to remove.
3.
Remove access plate (secured with (2) screws) from firebox ceiling.
4.
Locate and remove nuts securing air duct top to firebox; 2 nuts reached through access holes, 2 inside air duct.
5.
Remove air duct top.
Access Plate
Figure 15a

KOZY HEAT #816-CL CO-LINEAR VENT SYSTEM

The co-linear pipes included in this vent system are designed to extend up to 35 ft. (10.67m)
IMPORTANT: IDENTIFICATION: Exhaust Pipe: red marking.
Proper operation of this insert requires exhaust and combustion air pipes be connected to correct collars on termination
kit and insert air duct.
A. Carefully extend exhaust and combustion air intake pipes to equal total chimney length required.
NOTE: If using „stub‟ method for combustion air pipe, extending it is not necessary. Determine length needed from air duct on insert (4 ft.
(1.22 m) minimum) to above damper opening in existing chimney. Remove excess combustion air pipe from end without a collar.
Continue with Step B. below.
If using „Full Connection‟ method: Slide intake pipe (end without collar) over collar on termination cap. Secure with 3 self-tapping
B.
Place bead of sealant around inner edge at end of exhaust pipe (without collar / red marking) and slide onto corresponding collar on
termination cap (collar with label). Secure with 3 self-tapping screws (provided). Apply additional sealant around joint to ensure a
proper seal.
IMPORTANT: EXHAUST COLLAR ON FIREPLACE AIR DUCT IS ON RIGHT SIDE. INSTALL TERMINATION CAP WITH EXHAUST COLLAR
ON RIGHT SIDE.
INTAKE COLLAR
NOTE: Collar extends through bottom plate.
SHEET METAL SCREWS (3 TOTAL)
Figure 15b
INSTALLATION
screws (provided).
SEALANT
NOTE: Collar extends through middle divider plate
SEALANT
Your vent cap may look slightly different than one shown.
PAGE 15
T
ERMINATION CAP
EXHAUST COLLAR