Conversion Kit Instructions - kozy heat Minneapolis MPS-30 Installation And Operation Manual

Direct vent fireplace insert
Hide thumbs Also See for Minneapolis MPS-30:
Table of Contents

Advertisement

CONVERSION KIT INSTRUCTIONS

IMPORTANT: This fireplace is NAT gas ready. If converting to LP gas, do so now before installing into existing fireplace.
#OCK-A42N-I-MPS-PSE NAT GAS CONVERSION KIT / #OCK-A53L-I-MPS-PSE LP GAS CONVERSION KIT
WARNING: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturers instructions and
all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not
followed exactly, a fire, explosion or productions of carbon monoxide may result, causing property damage, personal injury
or loss of life. The qualified service agency is responsible for proper installation of this kit. The installation is not proper and
complete until operation of the converted appliance is checked as specified in the instructions supplied with the kit. Refer to
appliance owner‟s manual or product data plate for proper inlet and manifold pressure adjustments and orifice sizing.
IMPORTANT: For high altitude installations: Above 2000ft. (610m) US / 4500ft. (1372m) Canada, consult local gas distributor or authority
having jurisdiction for proper de-rating methods.
Kit includes:
(1) Gas Conversion Label
(1) Gas Type Label
WARNING: SHUT OFF GAS SUPPLY AND ELECTRICAL POWER TO FIREPLACE.
SHUT OFF GAS SUPPLY BEFORE DISCONNECTING ELECTRICAL POWER.
PREPARE THE FIREPLACE:
Remove screen front, glass frame assembly, and glass media from insert.
REPLACE BURNER ORIFICES:
1.
Remove back burner (secured with 2 screws).
2.
Remove front burner.
3.
Remove existing orifice cap. Replace with orifice cap included with kit, making
sure to tighten cap securely.
NAT. GAS: #42 orifice
L.P. GAS: #53 orifice
CONVERT PILOT ASSEMBLY:
1.
Remove (2) screws securing pilot assembly to pilot bracket. Place 7/16" wrench
on upper fitting and 1/2" wrench onto lower fitting, turn pilot hood nut
counter-clockwise to remove pilot hood.
2.
Remove pilot orifice located inside lower fitting and replace with one included
with kit.
3.
Re-attach pilot hood. Tighten with wrenches, making sure pilot hood is positioned
as shown in Figure 12d. Final alignment of sensor and hood outlet is critical for
proper ignition.
4.
Attach pilot assembly to pilot bracket with screws previously removed.
GAS TYPE CONVERSION:
Press and hold Learn Button on Main Control Module for 20 seconds (access hole on
right hand side of outer wrap). A beep will be heard letting you know the procedure has
been completed.
If converting from NAT to LP gas: one (1) second long beep
If converting from LP to Nat gas: three (3) second long beep
(2) Burner Orifices: NAT #42 / LP #53
(1) Pilot Orifice: NAT #.018 / LP #.012
PAGE 12
(1) Low Limit Screw: NAT #50 / LP #56
BURNER ORIFICES
NUT SECURING
FRONT ORIFICE
BRACKET
Figure 12a
Figure 12a
Lower fitting
Figure 12b
Pilot orifice:
Remove existing,
replace with one
included with kit
Figure 12c
Sensor
Align
Hood outlet
Figure 12d
Upper fitting
pilot bracket