GLASS FRAME / SCREEN FRONT
WARNING: DO NOT OPERATE THIS FIREPLACE WITH GLASS REMOVED, CRACKED OR BROKEN. REPLACEMENT OF GLASS FRAME
ASSEMBLY, #JOR-057T SHOULD BE DONE BY A LICENSED OR QUALIFIED SERVICE PERSON.
WARNING: DO NOT REMOVE THESE COMPONENTS WHEN HOT!
REMOVE GLASS FRAME ASSEMBLY
A. Locate spring-loaded latches securing glass frame assembly at bottom of firebox.
B.
Using glass latch tool (included in components packet) pull bottom latches out and „up‟
to release glass frame assembly latch tabs.
C.
Lift glass frame assembly up off tabs located at top of firebox.
INSTALL GLASS FRAME ASSEMBLY
A. Make certain bottom latches are pushed „down‟ to allow for easier installation.
B.
Align slots at top of glass frame assembly over tabs at top of firebox while lowering
bottom of glass frame assembly into position.
C.
Using glass latch tool, pull latches out and „down‟ over latch tabs to secure glass frame
assembly bottom.
SCREEN FRONT
(sold separately)
To install: Align tabs on back of frame with slots on insert, set into position.
To remove: Lift frame up and out of slots.
IMPORTANT: All steps as outlined in „PREPARE EXISTING FIREPLACE‟ must be completed before continuing with this installation.
IMPORTANT: Please refer to Matching Security Code instructions on pages 23-24 prior to installation. Easy access to LEARN button is reached through hole
on outer right side of insert before installation. After installation, some disassembly is required to reach LEARN button. After installation
LEARN button access instructions on pages 23-24 also.
IMPORTANT: Follow instructions included from vent pipe manufacturer as well as venting requirements as outlined in this installation manual.

APPROVED VENTING

MANUFACTURER
Kozy Heat
ICC
Selkirk
American Metals
Simpson Dura-Vent
Security
Metal Fab
RLH

COMBUSTION AIR VENTING OPTIONS

OPTION 1:
FULL CONNECTION: Combustion air intake pipe is run entire chimney length and connected to termination cap.
OPTION 2:
STUB VENTING: Combustion air intake pipe is extended a minimum of 4 ft. (1.22 m) past damper opening into
INSTALLATION
APPROVED CAPS
816-CL Vent System
TM-IVT
TM-SVT
4DT-VC
4DVC
46DVA-VCH
3PDVCV
4DVT
HS-C33U99
HS-C33F1313
HS-CD3333-1313
existing chimney. It is not connected to termination cap.
PAGE 14
Upper tab (1 ea. side)
Lower latch (1 ea. side)
Latch tab
Insert glass latch tool here
Figure 14a