CopperLink™ Model 2300
Long Range Ethernet Extender

Quick Start Guide

Important—This is a Class A device and is intended for use in a light industrial environment.
Part Number:
07MCL2300-QS
It is not intended nor approved for use in an industrial or residential environment.
Sales Office: +1 (301) 975-1000
Technical Support: +1 (301) 975-1007
E-mail: support@patton.com
WWW: www.patton.com

Advertisement

Table of Contents
loading

Summary of Contents for Patton CopperLink 2300

  • Page 1: Quick Start Guide

    Important—This is a Class A device and is intended for use in a light industrial environment. It is not intended nor approved for use in an industrial or residential environment. Sales Office: +1 (301) 975-1000 Part Number: Technical Support: +1 (301) 975-1007 07MCL2300-QS E-mail: support@patton.com WWW: www.patton.com...
  • Page 2 • This device contains no user serviceable parts. The equipment shall be returned to Patton Electronics for repairs, or repaired by qualified ser- vice personnel. WARNING • The external power adapter shall be a listed Limited Power Source. The mains outlet that is utilized to power the devise shall be within 10 feet (3 meters) of the device, shall be easily accessible, and protected by a circuit breaker.
  • Page 3: Hardware Installation

    Observe the signal/pin relationship on the CL2300’s Line interface jack for each pair in Figure Figure 4 shows the proper way to wire a cable with a RJ- 45 jack on one end and four RJ-11jacks on the other. CopperLink 2300 Quick Start Guide...
  • Page 4 CL2300 (RJ-45) twisted pair line interface Figure 2. CopperLink Pinout for two devices Figure 3. RJ-45 to RJ-11 cable Figure 4. CopperLink 2300 Quick Start Guide...
  • Page 5: Connecting Interfaces

    1 TX+ (data output, PoE+) 2 TX- (data output, PoE-) 3 RX+ (data input, PoE+) 4 (no connection) 5 (no connection) 6 RX- (data input, PoE-) 7 (no connection) 8 (no connection) Figure 6. CL230010/100Base-T RJ-45 Connector Pinout CopperLink 2300 Quick Start Guide...
  • Page 6 2.5 Router/Bridge Status LEDs The LEDs indicate the status of power, the WAN (CopperLink) PoE, and Ethernet connections. When powered down, the LED indicators are clear; when powered on, the LED indicators are yellow. Note CopperLink 2300 Quick Start Guide...
  • Page 7: Wizard Interface

    Earlier versions predating Internet Explorer 9.0 browser are not compatible with the CL2300. Note 3.1 Connect with Web GUI Connect the Ethernet cable. Connect the power supply. Connect via web browser to the default address 192.168.200.10 OR connect to 192.168.200.11 for 2 pack local units. CopperLink 2300 Quick Start Guide...
  • Page 8 The CL2300 includes a Wizard within the GUI. The Icon to the wizard is in the top right corner of your browser as it displays in figure Wizard Home page Figure 9. Once the wizard icon is selected, you will have the options of supported set ups as shown in figure 10. Click on CL2300 Basic Setup. CopperLink 2300 Quick Start Guide...
  • Page 9 - DHCP: The CL2300 management port will accept an IP address from a DHCP server. - Both: This choice will assign two IP addresses (one static and one DHCP to the management port - Management VLAN ID: (Optional) define a VLAN ID for management traffic. CopperLink 2300 Quick Start Guide...
  • Page 10 Configure Preview Option Figure 12. When the user chooses the save and reboot option a prompt will ask you to confirm. If the configuration is cor- rect, select “Yes” as shown in figure 13 CopperLink 2300 Quick Start Guide...
  • Page 11: Cli Operation And Configuration

    Typically the time to reboot and reestablish a CopperLink link and pass traffic once again will be under 2 min- utes. 4.0 CLI Operation and Configuration You can connect a PC to configure the CopperLink 2300 using the CLI. 4.1 Connect with SSH Connect the Ethernet cable.
  • Page 12 Local and Remote: This will set the Ethernet Extender as Local or Remote. Local is typically used at the net- work, Remote is typically used at the remote device or remote network. Your CopperLink 2300 when received in a 2pk is already configured one CL2300 as Local and one CL2300 as Remote.
  • Page 13: Additional Information

    Show: Displays all the configured options of the CL2300 CopperLink port(s). node(cfg)# show prt-line 0 0 5.0 Additional Information For detailed information about configuring and operating guidance, set up procedures, and troubleshooting, refer to the CopperLink 2300 Series User Manual available online at www.patton.com/manuals CopperLink 2300 Quick Start Guide...
  • Page 14 A Customer and Technical Support Toll-Free VoIP support: call sip:support@patton.com with a VoIP SIP phone Online support: www.patton.com E-mail support: support@patton.com—answered within 1 business day B Compliance B.1 EMC FCC Part 15, Class A • EN55022, Class A • EN55024 •...
  • Page 15 AC outlet (such that the computing equipment and receiver are on different branches). CopperLink 2300 Quick Start Guide...
  • Page 16: E Ec Declaration Of Conformity

    Oxford, OX1 1BE, UK F.1 Copyright statement Copyright © 2013, Patton Electronics Company. All rights reserved. The information in this document is subject to change without notice. Patton Electronics assumes no liability for errors that may appear in this document. F.2 Trademarks statement...