Athena C10 Communications Manual page 38

Platinum series universal digital controller
Hide thumbs Also See for C10:
Table of Contents

Advertisement

13. To select the Alarm Function, the value between 0 and 7 must be
assigned as per the below table:
Alarm Function
Disabled
Absolute active high
Absolute active low
Deviation active high
Deviation active low
Band active out
Heater break
Loop break alarm
N.B. Index 7 is available for first alarm output.
14. To select the Alarm output, the value between 1 and 3 must be
assigned as per the below table:
Alarm output
15. To select the Digital input function, the value between 0 and 8 must
be assigned as per the below table:
Digital Input function
Disabled
Local / Remote
Auto / Manual
st
1
Mem. Setpoint
nd
2
Mem. Setpoint
Keypad lock
Slopes Inhibition
PV Hold
Program Run/Hold
16. To select the Program Status, the value between 0 and 4 must be
assigned as per the below table:
Program Status
Reset
Hold Back (note)
Program End
Note. This function is automatically activated every time the PV exceed
the band limits set in each segment of the running program.
17. To select the Time base, the value between 0 and 2 must be
assigned as per the below table:
Time Base
Second
Minute
Serial Value
Serial Value
OP 1
OP 2
OP 3
Serial Value
Serial Value
Hold
Run
Serial Value
Hour
0
1
2
3
4
5
6
7
1
2
3
0
1
2
3
4
5
6
7
8
0
1
2
3
4
0
1
2
38