Installation
Table 8 Standard CRT-2 Settings for Use with NFS-640
Function Key
CRT-2 Parameters
F1: Quick
Emulation=CRT-2
("Read Status" key)
Comm Mode=Full Duplex
Enhanced=On
F2:Genrl
Emulation=CRT-2
("Alter Status" key)
Auto Font Load=On
Monitor Mode=Off
Host/Printer=EIA/Aux
F3: Displ
Page Length=24
("Prog" key)
Display Cursor=On
Columns=80
Scroll=Jump
F4: Kybd
Language=U.S.
("Spl Funct" key)
Keyclick=Off
Key Lock=Caps
F5: Keys
Enter Key=<CR>
("Prior" key)
Alt Key=Meta
Pound Key=U.S.
F6: Ports
EIA Baud Rate=9600
("Next" key)
Aux Baud Rate=9600
EIA Xmt=Xon-Xoff
Aux Xmt=Xon-Xoff
EIA Break=Off
Aux Break=Off
F7: Host
Comm Mode=Full Duplex
("Auto Step" key)
Recv <DEL>=Ignore
Send Block Term=<CR>
F8: Print
Prnt Line Term=<CR><LF>
("Activ Signal" key)
F9: Emul
Attribute=Page
WPRT Intensity=Dim
WPRT Blink=Off
Status Line=Off
F10
Setup Group F10 does not affect communications with the control panel.
F11
Setup Group F11 does not affect communications with the control panel.
F12: Prog
Program the function keys as follows: F1 ~A F2 ~B F3 ~C F4 ~D F5 ~E F6 ~F F7 ~G
("Ack Step" key)
F8 ~H F9 ~I F10 ~J F11 ~K F12 ~L F13 ~M F14 ~N F15 ~O F16 ~P Shift F13 ~Q

3.9.5 Connecting a PC

A PC can be hooked up to the Control Panel EIA-232 port to allow the VeriFire Tools programming
utility to upload and download the operating program of the control panel. Refer to the insert in the
VeriFire Tools CD and to the program's on-line help function for instructions.
Note: Download operations that change the basic program of the control panel must be performed
by responsible service personnel in attendance at the control panel. After downloading a program,
test the control panel in accordance with NFPA 72-1999.
54
EIA Baud Rate=9600
Aux Baud Rate=9600
Language=U.S.
Enhanced=On
Auto Page=Off
Bell Volume=09
Screen Length=26 Lines
Cursor=Blink Line
Width Change Clear=Off
Refresh Rate=60 Hz
Char Set Mode=ASCII
Key Repeat=Off
Keyboard Present=Yes
Return Key=<CR>
Disconnect=Pause
EIA Data Format=8/1/N
Aux Data Format=8/1/N
EIA Recv=Xon-Xoff(XPC)
Aux Recv=Xon-Xoff(XPC)
EIA Modem Control=Off
Aux Modem Control=Off
Local=Off
Send ACK=On
Null Suppress=On
Prnt Block Term=<CR>
Bright Video=Off
WPRT Reverse=Off
Display NV Labels=Off
Fkey Speed=Normal
NFS-640 Installation Manual P/N 51332:B1 12/01/2003
Installing Remote Printers and/or CRT
EIA Data Format=8/1/N
Aux Data Format=8/1/N
Host/Printer=EIA/Aux
Auto Wrap=Off
Auto Scroll=On
Warning Bell=On
Screen Video=Normal
Auto Adjust Cursor=On
Speed=Normal
Overscan Borders=Off
Key Mode=ASCII
Margin Bell=Off
Backspace=<BS>/<DEL>
Desk Acc=Disabled
EIA Parity Check=On
Aux Parity Check=On
EIA Xmt Pace=Baud
Aux Xmt Pace=Baud
EIA Disconnect=2 sec
Aux Disconnect=2 sec
Recv <CR>=<CR>
Send Line Term=<CR><LF>
Secondary Recv=Off
Page Edit=Off
WPRT Underline=Off
Save Labels=On