Sign In
Upload
Manuals
Brands
Notifier Manuals
Control Panel
NFS2-640/E
Notifier NFS2-640/E Manuals
Manuals and User Guides for Notifier NFS2-640/E. We have
2
Notifier NFS2-640/E manuals available for free PDF download: Installation Manual, Operation Manual
Notifier NFS2-640/E Operation Manual (76 pages)
Fire Alarm Control Panel
Brand:
Notifier
| Category:
Control Panel
| Size: 1.02 MB
Table of Contents
Fire Alarm System Limitations
2
Installation Precautions
3
Table of Contents
5
Section 1: General Information
8
UL 864 Compliance
8
About this Manual
8
1: Cautions and Warnings
8
2: Typographic Conventions
8
3: Supplemental Information
9
4: Shortcuts to Operating Functions
10
Introduction to the Control Panel
10
Section 2: Use of the Controls
11
Introduction
11
System Status Indicator Leds
11
Control Keys
12
1: Acknowledge/Scroll Display
12
2: Signal Silence
13
3: System Reset
13
4: Drill
13
5: Lamp Test
14
Programming Keypad
14
Section 3: Operation of the Control Panel
16
Overview
16
Normal Mode of Operation
16
Fire Alarm Mode of Operation
17
1: How the Control Panel Indicates a Fire Alarm
17
2: How to Respond to a Fire Alarm
17
3: Interpreting Fire Alarm Type Codes
18
System Trouble Mode of Operation
19
1: How the Control Panel Indicates a System Trouble
19
2: How to Respond to a System Trouble
20
Security Alarm Mode of Operation
21
1: How the Control Panel Indicates a Security Alarm
21
2: How to Respond to a Security Alarm
22
3: Interpreting Security Type Codes
22
Active Supervisory Signal Mode of Operation
22
1: How the Control Panel Indicates an Active Supervisory
22
2: How to Respond to an Active Supervisory
23
3: How to Interpret Supervisory Type Codes
24
Pre-Alarm Warning Mode of Operation
24
1: How the Control Panel Indicates a Pre-Alarm Warning
24
Pre-Alarm Alert and Action Levels
25
2: How to Respond to a Pre-Alarm Warning
25
Interpreting Pre-Alarm Type Codes
25
Disabled Points Mode of Operation
26
Non-Alarm Mode of Operation
26
1: Purpose of Non-Alarm Points
26
2: How the Control Panel Indicates an Active Fire Control
27
3: How the Control Panel Indicates an Active Non-Fire Point
27
CO Alarm Mode of Operation
27
1: How the Control Panel Indicates a CO Alarm
27
2: How to Respond to a CO Alarm
28
3: Interpreting CO Alarm/Supervisory Type Codes
28
Active Trouble Monitor Mode of Operation
29
1: How the Control Panel Indicates an Active Trouble Monitor
29
2: How to Respond to an Active Trouble Monitor
29
Output Circuit Trouble Mode of Operation
30
1: Overview
30
2: How the Control Panel Indicates a NAC Trouble
31
3: How the Control Panel Indicates a Control/Relay Trouble
31
4: How to Respond to a NAC or Control/Relay Trouble
31
Operation of Special System Timers
32
1: What Are System Timers
32
2: How to View System Timer Selections
32
3: How System Timers Work
32
Waterflow Circuit Operation
33
Style 6 and Style 7 Operation
33
Section 4: Read Status Operation
34
Introduction
34
What Is Read Status
34
1: Quick Reference Key Sequences
34
Entering Read Status
34
Viewing and Printing a Read Status
35
1: How to View Read Status of Devices, Zones, & System Settings
35
2: How to View Read Status for Event and Alarm History
45
3: How to Print Points, Event and Alarm History
46
4: How to View and Print Hidden Event and Alarm History
48
Appendix A, "Special Zone Operation
49
A.1: Overview
49
A.2: Releasing Zones (R0-R9)
49
A.2.1: Purpose of Releasing Zones
49
A.2.2: How to View Releasing Zone Selections
50
A.2.3: How Releasing Zones Operate
50
A.3: Time, Date, and Holiday Functions
52
A.3.1: Overview
52
A.3.2: How to View Time Control Selections
52
A.3.3: How to View Holiday Function Selections
53
A.3.4: How Time Control and Holiday Functions Work
53
A.4: NAC Coding
54
A.4.1: Overview of Coding
54
A.4.2: How to View Coding (F8) Selections
54
A.4.3: How to Respond to an Alarm with Coding
55
A.5: Presignal and Positive Alarm Sequence (PAS) Operation
55
A.5.1: Overview
55
A.5.2: What Is Presignal and PAS
55
A.5.3: How to View Presignal and PAS Selections
56
A.5.4: How to Respond to an Alarm with Presignal Delay Timer (no PAS)
56
A.5.5: How to Respond to an Alarm with Presignal Delay Timer (PAS Selected)
57
Appendix A: Special Zone Operation
49
Appendix B, "Intelligent Detector Functions
58
Appendix B: Intelligent Detector Functions
58
Appendix C, "Remote Terminal Access
60
C.1: General Description
60
C.2: Operating Modes
60
C.2.1: Local Terminal Mode (Loct)
60
C.2.2: Local Monitor Mode (Locm)
61
C.2.3: Remote Terminal Mode (Remt)
61
C.3: Using the CRT-2 for Read Status
62
C.3.1: Overview
62
C.3.2: Accessing Read Status Options
62
C.3.3: Read Point
63
C.3.4: Display Devices in Alarm or Trouble
63
C.3.5: Display All Programmed Points
64
C.3.6: Step-Through History
64
C.3.7: View All History
64
C.3.8: Step-Through Alarm History
64
C.3.9: View All Alarm History
64
C.4: Using the CRT-2 for Alter Status
65
C.4.1: Overview
65
C.4.2: Accessing Alter Status Options
65
C.4.3: Enable or Disable Detectors, Modules or Zones
66
C.4.4: Change Alarm and Pre-Alarm Levels
66
C.4.5: Clear Verification Counter
67
C.4.6: Clear the Entire History Buffer
67
C.4.7: Set the Pre-Alarm for Alert or Action
67
Appendix C: Remote Terminal Access
60
Appendix D: Point and System Troubles Lists
68
Appendix D, "Point and System Troubles Lists
68
D.1: Point (Device) Troubles
68
D.2: System Troubles
69
Index
72
Advertisement
Notifier NFS2-640/E Installation Manual (78 pages)
Fire Alarm Control Panel
Brand:
Notifier
| Category:
Control Panel
| Size: 3.12 MB
Table of Contents
Table of Contents
5
Section 1: about this Manual
7
Standards and Other Documents
7
UL 864 Compliance
8
1: Products Subject to AHJ Approval
8
Related Documents
8
Cautions and Warnings
10
Section 2: System Overview
11
System Description
11
1: Standard Features
11
2: Options
12
3: System Limitations
12
System Components
12
1: Basic Equipment
12
2: Control Panel Circuit Board
13
3: Main Power Supply (CPS-24/E)
13
4: Circuit Board Components
14
System Cabinets
16
Compatible Equipment
17
Section 3: Installation
19
Preparing for Installation
19
1: Standards and Codes
19
Installation Checklist
20
Mounting a Cabinet
20
Laying out Equipment in Cabinet and Chassis
21
Installing the Control Panel
25
1: Control Panel Circuit Board & Keypad/Display Unit
25
2: Using NCA-2 as Primary Display
26
Mounting Option Boards
27
1: Option Boards in the NFS2-640/E Chassis
27
2: Option Boards in CHS-4L
28
3: Option Boards on BMP-1 in Dress Panels
29
4: Transmitter Module TM-4
30
5: Loop Expander Module
30
6: Network Communications Module
31
7: DVC Digital Voice Command
32
Connecting the Power Cables
33
1: Overview
33
2: Connecting the Control Panel to AC Power
34
3: Checking AC Power
34
4: Installing and Connecting the Batteries
35
5: External DC Power Output Connections
35
6: Accessories DC Power Output Connections
36
NAC Connections and Releasing Circuits
37
1: Stat-X Devices
38
Output Relay Connections
38
Backup-Alarm Switches
39
UL Power-Limited Wiring Requirements
40
1: Labeling Modules and Circuits
41
Installing EIA-485 Devices
41
Installing Remote Printers And/Or CRT
41
1: Custom Cable Fabrication
41
2: Installing and Configuring the PRN Series Printer
42
3: Installing and Configuring a Keltron Printer
43
4: Installing and Configuring a CRT-2
44
5: Connecting Multiple Printers, Crts, or CRT/PRN Combination
46
Wiring a Signaling Line Circuit (SLC)
46
Connecting a PC for Off-Line Programming
47
Section 4: Applications
48
Overview
48
Devices Requiring External Power Supervision
48
NFPA 72 Central or Remote Station Fire Alarm System (Protected Premises Unit)
49
Central Station Fire Alarm System Canadian Requirements
51
NFPA 72 Proprietary Fire Alarm Systems
52
Fire/Security Applications
52
1: General Operation
52
2: Installing a Security Tamper Switch
53
3: Receiving Unit
53
4: Programming
53
5: Wiring for Proprietary Security Alarm Applications
54
Releasing Applications
55
1: Overview
55
2: Programming
55
3: Connecting a Releasing Device to the Control Panel
56
4: Connecting a Releasing Device to the FCM-1 Module
57
5: Connecting Releasing Devices to the FCM-1-REL Control Module
59
6: Connecting an NBG-12LRA Agent Release-Abort Station
60
Section 5: Testing the System
62
Acceptance Test
62
Periodic Testing and Service
62
Operational Checks
62
Battery Checks and Maintenance
63
Appendix A: Power Supply Calculations
64
A.1: Calculating AC Branch Circuit Current
64
A.2: Calculating the System Current Draws
64
A.2.1: Calculating the Maximum Secondary Power Fire Alarm Current Draw
66
A.3: Calculating the Battery Requirements
68
A.3.1: Calculating the Battery Capacity
68
A.3.2: Calculating the Battery Size
69
Appendix B: Electrical Specifications
70
B.1: Electrical Specifications
70
B.2: Wire Requirements
72
Appendix C: Canadian Applications
74
C.1: Standalone Application
74
C.1.1: NFS2-640/E with KDM-R2
74
C.1.2: NFS2-640/E with NCA-2
74
C.2: Local Network Application
74
C.3: Automatic Alarm Signal Silence
74
C.4: Annunciator Applications
74
C.5: Releasing Devices
74
Advertisement
Related Products
Notifier NFS2-3030/E
Notifier NFS2-3030
Notifier NFS2-640
Notifier NFS-C
Notifier NFS-320SYS
Notifier NFS-320SYSE
Notifier NFS-640
Notifier NFS-3030/E
Notifier NFS-320C
Notifier NFS-3030
Notifier Categories
Fire Alarms
Control Panel
Smoke Alarm
Control Unit
Security System
More Notifier Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL