The appliance is required to be inspected at least once a year by a
professional service person.
The compartment below the firebox (behind the lower grill) must be cleaned
at least once a year, more frequent cleaning may be required due to excessive
lint from carpeting, bedding materials, or other fibrous materials. It is im-
perative that the burner be cleaned once a year.
NOTE: INSTALLATION AND REPAIR SHOULD BE DONE ONLY
BY QUALIFIED SERVICE PERSON. THE APPLIANCE SHOULD
BE INSPECTED BEFORE USE AND ANNUALLY BY A QUALI-
FIED SERVICE PERSON. MORE FREQUENT CLEANING MAY
BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING,
BEDDING MATERIALS, ETC. IT IS IMPERATIVE THAT CON-
TROL COMPARTMENTS, BURNERS AND CIRCULATION AIR
PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN.
Pilot
FAN
The fan should be disconnected from electrical current, and cleaned
(vacuumed) every six months. The bearings are sealed and require no oiling.
VENT SYSTEM
Annual examination of the venting system by a qualified agency is required.
IF THE VENT-AIR INTAKE SYSTEM IS DISASSEMBLED FOR ANY
REASON, RE-INSTALL PER THE INSTRUCTIONS PROVIDED WITH
THE INITIAL INSTALLATION.
The flow of combustion and ventilation air must not be obstructed.
IMPORTANT: ANY SAFETY SCREEN OR GUARD REMOVED FOR
SERVICING MUST BE REPLACED PRIOR TO OPERATING THE
APPLIANCE.
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN
SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER
AND DANGEROUS OPERATION. VERIFY PROPER OPERATION
AFTER SERVICING.
CAUTION: KEEP THE APPLIANCE AREA CLEAR OF COMBUSTI-
BLE MATERIALS, SUCH AS GASOLINE AND OTHER FLAMMABLE
VAPORS AND LIQUIDS.
MAINTENANCE
Burner Orifice
PAGE 19
MILLIVOLT BOARD SYSTEM
Annual cleaning of the burner system is
required.
The burner assembly may be removed for easier
access. Refer to page 13 in this installation man-
ual for complete instruction on removing & rein-
stalling the burner assembly.
Visually
check
for
blocked
especially near the pilot. Blocked port holes may
cause delayed ignition.
R e i n s t a l l
t h e
b u r n e r
following instructions on page 13 of this
installation manual.
Visually check pilot light and burner when in
operation. The flames should be steady, not lifting
or floating.
GLASS CLEANING & REPLACEMENT
Clean glass only when cool and only with non-
abrasive cleansers.
Do not operate this fireplace with the glass/frame
assembly removed, cracked or broken.
The glass assembly, part #700-15T, shall only be
replaced as a complete unit, as supplied by Hus-
song Mfg. Co., Inc.
Replacement of the glass & frame assembly,
part #700-15T, must only be performed by a li-
censed or qualified service person.
DO NOT SUBSTITUTE MATERIALS.