MAINTENANCE REQUIREMENTS
1. The appliance should be inspected at least once a year
by a professional service person.
NOTE: INSTALLATION AND REPAIR SHOULD BE DONE
ONLY BY A QUALIFIED SERVICE PERSON. THE
APPLIANCE SHOULD BE INSPECTED BEFORE USE AND
AT LEAST ANNUALLY BY A QUALIFIED SERVICE PERSON.
MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO
EXCESSIVE LINT FROM CARPETING, BEDDING
MATERIALS, ETC. IT IS IMPERATIVE THAT CONTROL
COMPARTMENTS, BURNERS AND CIRCULATION AIR
PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN.
2. The compartment below the firebox (behind the lower
grill) must be cleaned at least once a year, more frequent
cleaning may be required due to excessive lint from
carpeting, bedding materials, or other fibrous materials. It
is imperative that the burner be cleaned once a year.
FAN
The fan should be disconnected from electrical current,
and cleaned (vacuumed) every six months. The bearings
are sealed and require no oiling.
VENT SYSTEM
Annual examination of the venting system by a qualified
agency is required.
IF THE VENT-AIR INTAKE SYSTEM IS DISASSEMBLED FOR
ANY REASON, REINSTALL PER THE INSTRUCTIONS
PROVIDED WITH THE INITIAL INSTALLATION.
The flow of combustion and ventilation air must not be
obstructed.
IMPORTANT:
ANY SAFETY SCREEN OR GUARD
REMOVED FOR SERVICING MUST BE REPLACED PRIOR
TO OPERATING THE APPLIANCE.
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION
WHEN SERVICING CONTROLS. WIRING ERRORS CAN
CAUSE IMPROPER AND DANGEROUS OPERATION.
VERIFY PROPER OPERATION AFTER SERVICING.
MILLIVOLT BOARD SYSTEM
1. Annual cleaning of the burner is required. The
burner & cover assembly may be removed for
easier access.
2. Refer to pages #33-#34 for complete instruction on
removing & reinstalling the burner & cover
assembly.
3. Visually check for blocked port holes, especially
near the pilot. Blocked port holes may cause
delayed ignition.
4. Replace the burner & cover following instructions
on pages #33-#34.
5. Visually check the pilot light and burner when they
are burning. The flames should be steady, not
lifting or floating.
#TMT-3875
Pilot
GLASS CLEANING & REPLACEMENT
C
Clean glass only when cool and only with non-
abrasive cleansers.
Do not operate this fireplace with the glass/frame
C
assembly removed, cracked or broken.
The glass assembly, Part #TMT-057T, shall only be
C
replaced as a complete unit, as supplied by
Hussong Mfg. Co., Inc.
C
Replacement of the glass assembly, Part #TMT-
057T, must only be performed by a licensed or
qualified service person. DO NOT SUBSTITUTE
MATERIALS.
Do not strike or slam glass door assembly.
C
CAUTION: KEEP THE APPLIANCE AREA CLEAR OF
COMBUSTIBLE MATERIALS, SUCH AS GASOLINE AND
OTHER FLAMMABLE VAPORS AND LIQUIDS.
Page 32
#TMT-3875-RF
Pilot
Burner Orifice

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tmt-3875-rf

Table of Contents