Error
Error message
code
0B80
BMC Memory Test Failed.
0B81
BMC Firmware Code Area CRC check failed.
0B82
BMC core hardware failure.
0B83
BMC IBF or OBF check failed.
0B8A
BMC SEL area full.
0B8B
BMC progress check timeout.
0B8C
BMC command access failed.
0B8D
Could not redirect the console - BMC Busy -
0B8E
Could not redirect the console - BMC Error -
0B8F
Could not redirect the console - BMC
Parameter Error -
0B90
BMC Platform Information Area corrupted.
0B91
BMC update firmware corrupted.
0B92
Internal Use Area of BMC FRU corrupted.
0B93
BMC SDR Repository empty.
0B94
IPMB signal lines do not respond.
0B95
BMC FRU device failure.
0B96
BMC SDR Repository failure.
0B97
BMC SEL device failure.
0B98
BMC RAM test error.
0B99
BMC Fatal hardware error.
0B9A
BMC not responding.
0B9B
Private I2C bus not responding.
0B9C
BMC internal exception.
0B9D
BMC A/D timeout error.
0B9E
SDR repository corrupt.
0B9F
SEL corrupt.
0BB0
SMBIOS - SROM data read error.
0BB1
SMBIOS - SROM data checksum bad.
0BC0
POST detected startup failure of 1st
Processor.
0BC1
POST detected startup failure of 2nd
Processor.
0BC2
POST detected startup failure of 3rd
Processor.
0BC3
POST detected startup failure of 4th
Processor.
Recommended Action
Turn off the power once and then on again to start the server. If
the error cannot be corrected, contact your service
representative.
All the commands and functions other than the FRU command
and the EMP function can be used. This is not a fatal error.
Turn off the power once and then on again to restart the server.
If the error cannot be corrected, contact your service
representative.
Turn off the power once and then on again to restart the server.
If the error cannot be corrected, contact your service
representative.
All the functions other than the function of accessing to SMC
through IPMB can be used. This is not a fatal error. Turn off the
power once and then on again to restart the server. If the error
cannot be corrected, contact your service representative.
All the commands and functions other than the FRU command
and the EMP function can be used. This is not a fatal error.
Turn off the power once and then on again to restart the server.
If the error cannot be corrected, contact your service
representative.
Turn off the power once and then on again to start the server. If
the error cannot be corrected, contact your service
representative.
Contact your service representative.
Contact your service representative to replace the processor.