How to use SENC convert window to initiate SENC conversion

Normally the "Automatic SENC conversion" is selected and there is no need to initiate SENC conversions from the
SENC convert window. If you do not use the "Automatic SENC conversion" , you need to manually initiate SENC
conversion. Another case in which you need to manually initiate SENC conversion is, if you upgraded or reloaded
the ECDIS software from the ECDIS software CD-ROM.
To initiate SENC conversions manually proceed as follows:
68 • • • • Vector Chart material
1. Press CHART PLAN button, select SENC Convert from the menu.
2. A SENC Convert window appears:
3. Use Cells to select an individual chart or use Groups to select a group of charts.
Then press Convert to initiate the SENC conversion of the charts. Note that the
Convert only do conversion of those charts, which are not currently converted into
the SENC format. If your selected chart or all members of your selected group are
already in the SENC format, the Conversion list remains empty. If all or some
charts are not yet in the SENC format, they are added into the Conversion list (see
example below). If you need for some reason to force SENC conversion of an
already converted charts, you read instructions in chapter "Seldom used features of
Vector charts" on page 144.
Note 1!. You can at any moment remove charts from the conversion list. You paint
with the cursor any amount of chart names in the Conversion List. And then you press
Cancel Conv. to remove your painted charts from the SENC conversion queue.
Note 2!. You can at any moment view the results of the finished SENC conversions.
Press Conv. History and you get a Conversion log for viewing.