2.4.6 RS-485 Auto Flow & RS-422 Master/Slave Modes
You can set the "Auto Flow Control" mode of RS-485 or "Master/Slave"
mode of RS-422 by using the SW3 DIP switch for COM1, COM2. Please
also refer to Table 2.9 for the COM port mapping with the DIP.
In RS-485, if the switch is set to "Off", the driver automatically senses
the direction of the data flow and switches the direction of transmission.
No handshaking is necessary.
In RS-422, if DIP switch is set to "On," the driver is always enabled, and
always in high or low status. Please refer below for the default setting.
Table 2.8: SW3 DIP Setting
SW3 Status
ON
OFF (Default)

2.4.7 Redundant RS-422 Matter

In the occasion that UNO-4683 RS-422 ports need to act as multi-master
in parallel with other RS-422 master ports. Because of the auto detection
function, the TX port will also receive data from other RS-422 master. To
avoid this situation in this kind of application, user can use SW5and SW7
to turn it off, then no data will be received from TX port. Please refer to
the Table 2.11 for the COM port mapping and refer to Figure 2.3 for the
location.
Table 2.9: Mapping table of switches for COM port
COM port
COM1
COM2
Description
RS-422: Master mode
RS-485: N/A
RS-422: Slave mode
RS-485: Auto flow control
Switches Status
SW5
ON: Normal (default)
OFF: RS-422 multi-master
SW7
19