30
Section D – Electrical Components
Key Switch
REMOVE AND REPLACE
Part mechanical, part electrical, the key switch gives the
operator three options: ON, OFF and LOCK.
CONTROL
PANEL
1.
Remove the control panel assembly (see Control
Panel Assembly, Remove and Re-install) and the
display module. Remove the display module rear
cover and the key.
NOTE: In this illustration, the control board insulator has
been removed for clarity.
2.
Remove three Phillips head screws and lift the switch
assembly away from the housing.
3.
Noting their locations, transfer the wires to the
replacement switch.
4.
Installation is the reverse of removal.
INTERLOCK
SWITCH
KEY
SCREWS
KEY SWITCH
ASSEMBLY
DISPLAY
MODULE
SWITCH
ASSEMBLY
SCREWS
Interlock Switch Assembly
REMOVE AND RE-INSTALL
The interlock switch assembly is a safety feature. The
switch prevents the compactor from operating unless the
door is safely closed.
1.
Remove the control panel assembly from the unit (see
Control Panel Assembly, Remove and Re-install).
2.
Noting their locations, transfer the wires to the
replacement switch assembly.
3.
Remove two Phillips head screws and the interlock
switch assembly from the display panel.
4.
Installation is the reverse of removal.
WIRES
SCREWS