4. Operating instructions
4.3 Prolonged absence
4.3.1
Switching off the appliance
If the central heating system is not used for a long period, we
recommend switching the boiler off.
1. Switch the boiler off.
4.3.2
Antifreeze protection
The boiler must be installed in a frost-free environment.
We recommend setting the boiler thermostat to a value off 10°C if
using a classic installation.
If the temperature of the central heating water in the boiler falls too
much, the integrated protection device switches itself on:
- If the water temperature is lower than 7°C, the circulating pump is
activated.
- If the water temperature is lower than 3°C, the boiler is activated.
- When the water temperature is above 10 °C, the boiler is switched
off and the circulation pump runs for another 15 minutes.
8
2. Cut the power supply to the boiler.
3. Close the gas valve.
DTG 1300-24 Eco / V130
11/09/09 - 300010111-001-B