Caractéristiques Techniques; Technical Characteristics - DeDietrich ECODENS DTG 1300-24 Eco / V130 User Manual

Gas fired condensing boiler
Table of Contents

Advertisement

7 Technical characteristics

DTG 1300-24 Eco / V130
Boiler
Specifications of the heating circuit
Domestic hot water specifications
Electrical specifications
Dimensions
(1) Heat exchanger inlet temperature : 80 °C
Domestic hot water temperature : 45 °C
(2) DHW setting : 60 °C
Average domestic hot water temperature : 40 °C
Boiler setting : 80 °C
(3) Cold water temperature : 10 °C
11/09/09 - 300010111-001-B
Nominal useful output 50/30 (Heating mode)
Nominal useful output (DHW mode)
Nominal input power (heating and DHW modes)
Minimum useful output 50/30 (Heating mode)
Minimum input power (heating and DHW modes)
Gas flow rate at Pn (à 15°C - 1013 mbar) Natural gas H (G20)
Gas flow rate at Pn
Nominal efficiency 80/60
Nominal efficiency 40/30
Maximum temperature (Safety thermostat cut-off)
Nominal water flow (
T = 20 K)
Rated net head (à 1000 l/h)
Flow temperature
Maximum pressure
Minimum operating pressure
Instruction set outlet temperature
Specific flow at ∆T = 30K (2) (3)
Flow per hour at ∆T = 35K (1) (3)
Flow in 10 min at ∆T = 30K (2) (3)
Electrical connection
Power consumption
Degree of protection
Height
Width
Depth
Shipping weight
DTG 1300-24 Eco / V130
kW
kW
kW
kW
kW
3
m
/h
3
Natural gas L (G25)
m
/h
Butane (G30)
Kg/h
%
%
°C
l/h
mCE
°C
bar
bar
°C
l/min
l/h
l/10 mm
V / Hz / A
W
mm
mm
mm
kg
7. Technical characteristics
23.7
23.7
22.8
6.0
5.9
2.41
2.80
1.79
96.8
108
110
1000
1
30 - 90
3
0.3
40 - 60
22.5
580
225
230 / 50 / 6
30 - 200
IPX2D
1520
600
647
196
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents