Switching Off The Boiler; Precautions To Take If There Is A Danger Of Frost; Precautions To Take In The Event Of Prolonged Shutdown (One Year Or More); Checking And Maintenance - DeDietrich DTG 230 S Manual

Gas-fired boilers
Table of Contents

Advertisement

3. Description

4.3 Switching off the boiler

Set the On/Off switch to 0.
DIEMATIC-m3 control panel
The panel must always be supplied with 230V voltage:
- to ensure the anti-grip of the heating pump,
4.3.1

Precautions to take if there is a danger of frost

Heating circuit:
Use a correctly dosed antifreeze to prevent the heating water
freezing. If this cannot be done, drain the system completely. In all
cases, consult the fitter.
4.3.2

Precautions to take in the event of prolonged shutdown (one year or more)

- Close the gas valve
- The boiler and the chimney must be swept carefully.

5 Checking and maintenance

Make the following checks at least 1 time a year:
- Checking the ignition burner
- Safety devices
- Water level
- Checking burner safety
- Checking the safety thermostat
- Checking the downdraught thermostat
Carry out the following maintenance at least 1 time a year:
- Cleaning main burner and ignition burner
- Cleaning of the heating body
- Cleaning painted surfaces
10
- to ensure Titan Active System® operation when a titanium anode
is protecting the DHW tank.
Use the mode:
- summer to shut down the heating.
- antifreeze to shut down the boiler if you are to be absent.
Domestic hot water circuit:
Drain the domestic water tank and pipes.
- Close the door of the boiler to prevent the internal circulation of air.
DTG 230
09/03/2016 - 300011506-02