3. Description

3 Description

3.1 General description

ECODENS boilers are floor-standing gas-fired condensing boilers.
They are combined with a 130 litre tank to handle domestic hot water
production and central heating using radiators or underfloor heating.

3.2 Control panel

N Temperature display
O Domestic hot water temperature maintenance
override button
P Safety shutdown light
Q Reset button
R Button -
S Button +
T 6-position switch
U "Heating" on light
V Heating temperature setting
W Flame presence light
X Setting the domestic water temperature
Y "Domestic hot water" on light
Z Pressure indicator
6
The boilers can operate on natural gas or on butane/propane. They
are factory set for natural gas H.
The display shows the temperature of the water in the domestic hot water heating outlet when
there is a request for domestic hot water.
With Easymatic remote control:
Pressing the button for 1 second makes it possible to override domestic hot water tank loading
outside the time period programmed in the control unit up to midnight (indicator light O2 flash).
- Light O1 lit : The burner is ignited to reheat the domestic hot water tank.
- Light O2 off : No override or programme running.
- Light O2 lit : Comfort programme activated.
Indicates an error in the boiler.
To restart the boiler after safety shutdown.
Used only in measurement
Used only in sweep mode
.
-
: Stop / Anti-freeze / Bleed.
-
: Domestic hot water (Summer).
-
: Heating and domestic hot water (Winter).
-
: Measurement mode (Key to access the parameters reserved for the installer).
-
: Fitter mode (Key to access the parameters reserved for the installer).
-
: Sweeping mode (Key to access the parameters reserved for the installer).
The light is on when the heating/domestic hot water reversal valve is in the heating position and the
circulator pump is operating.
Setting range: 30 °C to 90 °C (Hard spot at 68°C).
The light is on when the burner is operating.
Setting range: 40 °C to 60 °C (Hard spot at 55°C).
The light is on when the heating/domestic hot water reversal valve is in the domestic hot water
position and the circulator pump is operating.
Indicates the pressure in the heating circuit from 0.5 to 2.5 bar.
DTG 1300-24 Eco / V130
, installer
and sweep
mode.