OPERATION

4.05 HF TIG (GTAW) Setup (201TS only)

Secure the gas cylinder in an
upright position by chaining it
to a stationary support to prevent
falling or tipping.
HF TIG (GTAW) Sequence of Operation
Before any welding is to begin, be sure to wear all appropriate and recommended safety equipment.
1. Switch the ON/OFF Switch (located on the rear panel) to OFF.
2. Connect the ground (work) clamp cable to positive output terminal. It is essential that the male plug is inserted
and turned fully clockwise until connector locks in place to achieve reliable electrical connection.
Manual 0-5148
Switch to 2T/4T
Set Welding Current
as specified by the
Electrode Manufacturer.
Negative
Output
Terminal
(Dinse™ 50)
Figure 4-5: Setup for HF TIG (GTAW) Welding of 201TS
THERMAL ARC 161STL, 201TS
Positive Output
Terminal
(Dinse™ 50)
CAUTION
4-9
Set Process Selection
Switch to LIFT TIG or HF TIG.
Set DOWN Slope
Art # A-10100_AB