Daikin RZQG71~140L7V1B Service Manual page 92

Skyair gqi-eco series heat pump r-410a 50hz
Table of Contents

Advertisement

ESIE12-06
10. DAY OF THE WEEK INDICATOR
11. CLOCK DISPLAY
12. MAXIMUM SET TEMPERATURE
13. MINIMUM SET TEMPERATURE
14. SCHEDULE TIMER ICON
15. ACTION ICONS
16. OFF ICON
17. INSPECTION REQUIRED
18. SET TEMPERATURE DISPLAY
19. SETTING
20. AIRFLOW DIRECTION ICON
21. NOT AVAILABLE
22. FAN SPEED ICON
23. DEFROST/HOTSTART MODE ICON
24. AIR FILTER CLEANING TIME ICON
25. ELEMENT CLEANING TIME ICON
26. VENTILATION MODE BUTTON
27. VENTILATION AMOUNT BUTTON
28. INSPECTION/TEST OPERATION BUTTON
29. PROGRAMMING BUTTON
30. SCHEDULE TIMER BUTTON
31. TIME ADJUST BUTTON
32. TEMPERATURE ADJUST BUTTONS
33. OPERATION CHANGE/MIN-MAX BUTTON
34. SETPOINT/LIMIT BUTTON
Remote Controller
The day of the week indicator shows the current week day (or the set day when reading or
programming the schedule timer).
The clock display indicates the current time (or the action time when reading or
programming the schedule timer).
The maximum set temperature indicates the maximum set temperature when in limit
operation.
The minimum set temperature indicates the minimum set temperature when in limit
operation.
This icon indicates that the schedule timer is enabled.
These icons indicate the actions for each day of the schedule timer.
This icon indicates that the OFF action is selected when programming the schedule timer.
These icons indicate that inspection is required. Consult your installer.
This indicates the current set temperature of the installation (not shown in LIMIT operation or
in FAN or DRY mode).
Not used, for service purposes only.
This icon indicates the airflow direction (only for installations with motorised airflow flaps).
is displayed whenever a non-installed option is addressed or a function is not
available.
This icon indicates the set fan speed.
This icon indicates that the defrost/hotstart mode is active.
This icon indicates the air filter must be cleaned. Refer to the manual of the indoor unit.
This icon indicates the element must be cleaned (HRV only).
The ventilation mode button operates the HRV; refer to the manual for more details.
This button sets the ventilation amount; refer to the manual for more details.
Not used, for service purposes only.
This button is a multi-purpose button.
Depending on the previous manipulations of the user, the programming button can have
various functions.
This button enables or disables the schedule timer.
These buttons are used to adjust the clock or, when in programming mode, to adjust the
programmed action time. Both buttons have an auto-repeat function.
These buttons are used to adjust the current setpoint or, when in programming mode, to
adjust the programmed setpoint temperature (step = 1°C). Both buttons are also used to
adjust the day of the week.
This button is a multi-purpose button. Depending on the previous manipulations of the user,
it can have following functions:
1 select the operation mode of the installation (FAN, DRY, AUTOMATIC, COOLING,
HEATING)
2 toggle between minimum temperature and maximum temperature when in limit operation
This button toggles between setpoint, limit operation or OFF (programming mode only).
and
Wired Remote Controller
81