Function of Main Components and Thermistors

1. Function of Main Components and Thermistors

RZQG71L
R2T R3T
Indoor heat exchanger
R1T
Indoor unit
RZQG100-140L
R2T R3T
Indoor heat exchanger
R1T
Indoor unit
94
Field piping φ 9.5
C1220T-O
Field piping φ 15.9
C1220T-O
Stop valve
(with service port 5/16" flare)
Field piping φ 9.5
C1220T-O
Field piping φ 15.9
C1220T-O
Stop valve
(with service port 5/16" flare)
(B) Electronic
expansion valve
Filter
Filter
R6T
(C) Four way valve
Check valve
Pressure
switch
(high)
S1PH
R3T
Compressor
Accumulator
Accumulator
(A) Compressor
Outdoor unit
* This thermistor is near the el. compo. box.
(B) Electronic
expansion valve
Filter
Filter
R6T
(C) Four way valve
Pressure
switch
(high)
S1PH
R3T
Compressor
Accumulator
Accumulator
(A) Compressor
Outdoor unit
* This thermistor is near the el. compo. box.
Outdoor
R4T
heat exchanger
R5T
Service port
(5/16" flare)
R2T
C: 3D069535
R4T
Outdoor
heat exchanger
R5T
Service port
(5/16" flare)
R2T
C: 3D069536
Function and Control
ESIE12-06
*
R1T
*
R1T