Electrolux GS 23 CH Service Manual page 57

Electrolux dishwasher service manual
Hide thumbs Also See for GS 23 CH:
Table of Contents

Advertisement

Remove front and rear base plate
Spares Operation 07.02 A. B.
-
Unscrew cable conduit.
-
Loosen pump support from the
base.
Pump support
-
Fold up the base as shown in the
photograph. Now you can dismount
the water softener system.
-
You have now better access to the
pressure control device, too.
No folding up of the appliance
required for dismounting.
- 57 -
599 51 13 34