Zebra Adjustment - Sony DIGITAL BETACAM DVW-707 Maintenance Manual

Digital betacam camcorder
Hide thumbs Also See for DIGITAL BETACAM DVW-707:
Table of Contents

Advertisement

4-19. Zebra Adjustment

4-19. Zebra Adjustment
Preparation
. ZEBRA switch (viewfinder) → ON
. On the setup menu, set as follows.
PAGE
: E12*FUNCTION 1/2
: TEST OUT → R, G or B
ITEM
PAGE
: E15*VF SETTING
: ZEBRA SELECT → 1
ITEM
: ZEBRA1 APT. LVL → l%
ITEM
. OUTPUT/DCC switch (inside panel) → CAM/ON
. Shoot a grayscale chart in the full underscanned monitor
frame.
Equipment
: Waveform monitor
Test point
: TEST OUT connector
Setting point
: 1 Lens IRIS
: A = 100 ± 2 IRE (NTSC)
Spec.
A = 700 ± 14 mV (PAL)
Adjustment Procedure
Equipment
: Waveform monitor
Test point
: TEST OUT connector
1. On the setup menu, adjust as follows.
PAGE
: E15*VF SETTING
ITEM
: ZEBRA1 DET. LVL
Spec.
: Set the condition that zebra pattern
appears at the portions A.
A
2. On the setup menu, set as follows.
PAGE
: E12*FUNCTION 1/2
: TEST SAW → ON
ITEM
3. On the setup menu, adjust as follows.
PAGE
: E15*VF SETTING
ITEM
: ZEBRA1 APT (Factory setting: 10%)
Spec.
: Adjust for the desired width of detection.
4-18
A
A
4. On the setup menu, set as follows.
PAGE
: E12*FUNCTION 1/2
: TEST SAW → OFF
ITEM
5. On the setup menu, set as follows.
PAGE
: E15*VF SETTING
: ZEBRA SELECT → 2
ITEM
6. On the setup menu, adjust as follows.
PAGE
: E15*VF SETTING
ITEM
: ZEBRA2 DET. LVL
Spec.
: Set the condition that zebra pattern
appears at the portion B.
Setting After Adjustment
. On the setup menu, set as follows.
PAGE
: E15*VF SETTING
: ZEBRA SELECT → 1
ITEM
PAGE
: E12*FUNCTION 1/2
: TEST OUT → ENC
ITEM
B
DVW-790WS/709WS/707
DVW-790WSP/709WSP/707P P1

Hide quick links: