5-15. Zebra Adjustment

Preparation
. ZEBRA switch (viewfinder)
. On the setting menu, set as follows.
PAGE
: FUNCTION 1/2
ITEM
: TEST OUT
PAGE
: VF SETTING
ITEM
: ZEBRA SELECT
ITEM
: ZEBRA1 APT
. OUTPUT/DCC switch (inside panel)
. Shoot a gray-scale chart in the full underscan's picture
frame.
: 1Lens IRIS
Setting point
: A = 100 ±2 IRE (NTSC)
Spec.
A = 700 ±14 mV (PAL)
Adjustment procedure
Test point : TEST OUT connector
1. On the setting menu, adjust as follows.
PAGE
: VF SETTING
ITEM
: ZEBRA1 DETECT
Spec.
: Set the condition that zebra pattern appear
at the portions A.
A
2. On the setting menu, set as follows.
PAGE
: FUNCTION 1/2
ITEM
: TEST SAW
3. On the setting menu, adjust as follows.
PAGE
: VF SETTING
ITEM
: ZEBRA1 APT (Factory setting : 0)
Spec.
: Set the desired width of detection.
4. On the setting menu, set as follows.
PAGE
: FUNCTION 1/2
ITEM
: TEST SAW
DNW-7/90/90WS
ON
R, G or B
1
MIN
CAM/ON
A
A
ON
OFF
5. On the setting menu, set as follows.
PAGE
: VF SETTING
ITEM
: ZEBRA SELECT
6. On the setting menu, adjust as follows.
PAGE
: VF SETTING
ITEM
: ZEBRA2 DETECT
Spec.
: Set the condition that zebra pattern appear
at the portion B.
Setting after adjustment
PAGE
: VF SETTING
ITEM
: ZEBRA SELECT
5-15. Zebra Adjustment
2
B
1
5-11