2-5. Displaying the Slack Information in the Past

2-5. Displaying the Slack Information in the Past
The slack information indicating a maximum of four slacks that have occurred in the past, can be dis-
played, using the VTR (DIAG) menu of the unit.
Refer to Section "3-2. VTR (DIAG) menu" for details of the VTR (DIAG) menu. Display the slack
information as follows.
1
Select the page DIAG-9 of the DIAG menu (VF screen : VTR MENU-13 page, 7. SLACK).
2
Select the SLACK DATA 1 to SLACK DATA 4. (The SLACK DATA 1 is the newest information.)
Display panel
9X XXXX
STATE CODE
TROUBLE CODE
1. SLACK DATA 1
2. SLACK DATA 2
3. SLACK DATA 3
4. SLACK DATA 4
VF screen
VTR MENU-13
SERVO MEMORY
1. CAP FREE SP
XX
2. PG PHASE-1
XX
3. PG PHASE-2
XX
4. CFGA DUTY
XX
5. CFGB DUTY
XX
6. EDIT DELAY
XX
7. SLACK
XXXX XXXX XXXX XXXX
SLACK
1
2
3
DATA
2-4
Contents of slack trouble
code
10 : Abnormal drum drive voltage
11 : No drum FG output
12 : No drum PG output
20 : Abnormal capstan drive
voltage
21 : No capstan FG-A output
22 : No capstan FG-B output
23 : Abnormal forward/reverse
rotation of capstan
24 : Abnormal capstan speed
(high-speed)
32 : No S reel FG output
42 : No T reel FG output
61 : Time over the forward
rotation time of function cam
62 : Time over the reverse
rotation time of function cam
63 : Time over the tape top
sensor
64 : Time over the full top sensor
65 : Time over the end sensor
time
4
70 : Servo NVRAM checksum
error
71 : Communication error
between servo CPUs
Contents of slack state code
00 : Power-on initialization
1x : No cassette and standby state
2x : Record
3x : Stop
4x : FF/REW
5x : Playback
6x : REC PAUSE
7x : REC REVIEW
8x : Threading/unthreading
DVW-790WSP/709WSP/707P P1
DVW-790WS/709WS/707