SET MODE
D Scan resume timer
The scan resume condition can be set as a pause (P5) or
timer scan (15/10/5). When a signal disappears, scan re-
sumes after 5 sec. has passed regardless of the setting.
15/10/5 : Scan pauses for 15, 10 or 5 sec. when a signal is
detected, then resumes after that.
P5
: Scan pauses until the signal disappears and then
resumes after 5 sec. (Default and recommended
setting).

Scan resume timer

P5 (default)
D Scan restart function
This function starts the scan after the transmission is per-
formed during scan and 10 sec. has passed.
Scan restart timer
OFF (default)
44
10 sec. setting
Scan restart timer ON
D Roger Beep
This function emits a beep on the communication party to
inform the transmission is fi nished.
Roger beep OFF (default)
Roger beep ON