Burner Information; Complete The Assembly; Install On/Off Switch; Install The Front Plate - Vermont Castings Intrepid INDVRCB Homeowner's Installation And Operating Manual

Direct vent, rear vent gas heater
Hide thumbs Also See for Intrepid INDVRCB:
Table of Contents

Advertisement

Intrepid® Direct Vent - Rear Vent Gas Heater

Burner Information

The appliance must only use the gas specified on the
rating plate, unless converted using a Vermont Castings
Fuel Conversion Kit. Refer to Page 42 for correct Fuel
Conversion Kit for your stove model.
Coversion instructions are provided with each kit and
beginning on Page 34 of this manual.
THIS APPLIANCE SHOULD BE CONNECTED TO
THE GAS SUPPLY ONLY BY A QUALIFIED GAS
SERVICE TECHNICIAN. FOLLOW ALL LOCAL
CODES.
THERE MUST BE A GAS SHUT-OFF BETWEEN
THE STOVE AND THE SUPPLY.

Complete the Assembly

• Open the swiveling latches (cams) on the top left
and right corners of the glass frame.
• Position the glass and frame against the firebox by
placing the bottom edge on the brackets on the bot-
tom face of the firebox.
• Swing the assembly against the firebox, and close
the latches firmly against the pins protruding from
the firebox top.

Install ON/OFF Switch

The switch assembly parts are found in the parts bag.
1. Apply wiring harness to the ON/OFF switch termi-
nals then insert into cut out on switch housing. The
ON/OFF switch will 'snap' into the cutout. (Fig. 55)
2. Run wires through cut out in side of shroud, under
bottom of rear shroud to valve.
3. Using supplied #10 x 1/2" screws, attach switch
housing over cut out opening in rear shroud.
4. Attach wires to valve terminals. (Fig. 56)
Wire
Harness
Switch
Assembly
Screw
Fig. 55 Attach switch assembly to rear shroud.
28
Fig. 56 Attach switch wires to valve.
Grasp the Front Plate and lift it into position, engaging
the two steel tabs at the upper corners behind the adja-
cent bosses in the Side Plates. (Fig. 57) Seat the Front
against the Sides so that the tabs at the bottom lip
engage with the notches in the edge of the stove base.
When properly installed, the bottom of the Front Plate
cannot be pulled away from the sides without also lifting
it up.
If you are installing optional Warming Shelves, do so
now, according to the instructions supplied with that kit.
Bottom Tabs Engage
Notch in Base
Fig. 57 Install stove front.
Use only a thermostat rated for 500 - 750 millivolts.
Check the table below for the appropriate gauge ther-
mostat wire to use for the length of lead required in your
installation.
Thermostat
Wire / Gauge
1. Install the wall thermostat in the desired location and
run the wires to the stove location. Terminate these
leads with 1/4" female connectors.
2. Connect the thermostat wires to the valve. (Fig. 56)
ST1120
This completes assembly of the Intrepid stove.

Install the Front Plate

ST228
attach switch
wires to valve
12/99

Thermostat Connection

ST967
(Optional) R Models Only
Intrepid install front
7/07
Maximum Run
18
40 feet
20
25 feet
22
16 feet
ST228
ST967
20012761

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents